2011
DOI: 10.1088/1009-0630/13/2/07
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Neutron Flux at the Initial Phase of Discharge in EAST

Abstract: Neutron emission in EAST was investigated by a time-resolved monitor system which consists of four 3 He proportional counters and a 235 U fission chamber. The D-D neutron flux increased approximately an order of magnitude during the 27 MHz ion-cyclotron radio frequency (ICRF) heating, demonstrating that the ICRF wave heated the plasma effectively. In addition in lower hybrid wave (LHW) experiment with higher plasma parameters D-D neutrons were also detected. However, masses of photoneutrons were generated in O… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0
2

Year Published

2013
2013
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 12 publications
0
14
0
2
Order By: Relevance
“…where the γ values are given by equation (21). Thus, the probability function is the fraction of the gyro-orbit that leads to neutrons with energies within the given neutron energy range.…”
Section: Analytic Expressions For Neutron Spectrometry Weight Functionsmentioning
confidence: 99%
See 3 more Smart Citations
“…where the γ values are given by equation (21). Thus, the probability function is the fraction of the gyro-orbit that leads to neutrons with energies within the given neutron energy range.…”
Section: Analytic Expressions For Neutron Spectrometry Weight Functionsmentioning
confidence: 99%
“…γ (E n ) is found by inserting v n = 2En mn in equation (21). In energy-pitch coordinates, the probability becomes…”
Section: Analytic Expressions For Neutron Spectrometry Weight Functionsmentioning
confidence: 99%
See 2 more Smart Citations
“…Thus, the development of a wide dynamic range NFM system that covers low Y n s in a radio-frequency (RF) wave-heating scenario, and high Y n s under NBI conditions is necessary for EAST fusion-neutron measurement. However, in the early operation stage of EAST, with only the activation of RF heating, the NFM system mainly relies on high-sensitivity 3 He counters; these counters are ill suited to high Y n conditions after NBI system operation [11]. Thus to upgrade the NFM detector, a 235 U fission chamber (FC) and a signal-processing digitizer were added relatively recently.…”
Section: Introductionmentioning
confidence: 99%