Measurement of refractive index variation of liquids by surface plasmon resonance and wavelength-modulated heterodyne interferometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 32 publications
(12 citation statements)
references
References 19 publications
0
8
0
Order By: Relevance
“…Recently, the photonic spin Hall effect combined with weak value amplification was employed to measure the optical conductivity of graphene, demonstrating that it varies significantly for different thicknesses of graphene layers and is proportional to the number of graphene layers . In this regard, we should point out that the thickness and flatness of the gold film used in this work will definitely impact on the quality of the data obtained in the present experiments, as they affect the refractive index and the penetration depth of the gold film, hence the experiment results. Besides, surface plasmon resonance combined with weak value amplification can start with a much lower initial light intensity with a good-quality gold film, thus increasing the dynamic range and measurement resolution for intensity-based detection. , The gold film deposited on the BK7 prism surface in our work was fabricated by thermal vacuum evaporation, which has nanometer variation in both flatness and thickness …”
Section: Resultsmentioning
confidence: 81%
“…Recently, the photonic spin Hall effect combined with weak value amplification was employed to measure the optical conductivity of graphene, demonstrating that it varies significantly for different thicknesses of graphene layers and is proportional to the number of graphene layers . In this regard, we should point out that the thickness and flatness of the gold film used in this work will definitely impact on the quality of the data obtained in the present experiments, as they affect the refractive index and the penetration depth of the gold film, hence the experiment results. Besides, surface plasmon resonance combined with weak value amplification can start with a much lower initial light intensity with a good-quality gold film, thus increasing the dynamic range and measurement resolution for intensity-based detection. , The gold film deposited on the BK7 prism surface in our work was fabricated by thermal vacuum evaporation, which has nanometer variation in both flatness and thickness …”
Section: Resultsmentioning
confidence: 81%
“…A quasi-linear dependence of the RI change of the salt solution's concentration (wt. %) is possible [25]. Various RIs can be adjusted by mixing with different weights of water and salt.…”
Section: Resultsmentioning
confidence: 99%
“…And these methods can roughly divide into fiber type sensor [41,[44][45]49] and non-fiber type sensor [42-43, 46-48, 50]. In this section, we will review some recent development in both type sensors for measuring concentration of the specific chemical compound [41][42][43][44][45][46][47][48][49][50].…”
Section: Concentration Measurement With Heterodyne Interferometermentioning
confidence: 99%
“…Heterodyne phase detection techniques offer the high measurement performance high sensitivity and high resolution in real-time. J. Y. Lee [43] proposed wavelength-modulation circular heterodyne interferometer (WMCHI) with SPR sensor for measuring the different concentration of alcohol. The diagram of the WMCHI is shown in figure 26.…”
Section: Concentration Measurement With Heterodyne Interferometermentioning