2020
DOI: 10.1021/acssensors.0c00346
|View full text |Cite
|
Sign up to set email alerts
|

Measurement of Chiral Molecular Parameters Based on a Combination of Surface Plasmon Resonance and Weak Value Amplification

Abstract: A novel combination of surface plasmon resonance (SPR) and weak value amplification (WVA) is employed to measure the optical rotation angle and refractive index of chiral enantiomers such as sugars and amino acids. An extremely low optical rotation change (2.73 × 10 −4 rad) is readily measurable, with a resolution of 6.75 × 10 −7 rad, 1 order of magnitude higher than that obtained using weak value amplification with intensity modulation, and a refractive index change of 1.13 × 10 −6 RIU is also detected, with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(8 citation statements)
references
References 43 publications
0
8
0
Order By: Relevance
“…SPR combined with weak value amplification (WVA) has recently been demonstrated in intensity detection of the refractive index of an optically inactive molecular solution, achieving a resolution several orders of magnitude higher than traditional SPR sensors [313]. The useful signal was amplified by several orders of magnitude by selecting appropriate pre‐selected and post‐selected states in a quantum‐mechanical measurement process, while technical noise was suppressed.…”
Section: Chiral Resolution Np Sensing Approachesmentioning
confidence: 99%
See 1 more Smart Citation
“…SPR combined with weak value amplification (WVA) has recently been demonstrated in intensity detection of the refractive index of an optically inactive molecular solution, achieving a resolution several orders of magnitude higher than traditional SPR sensors [313]. The useful signal was amplified by several orders of magnitude by selecting appropriate pre‐selected and post‐selected states in a quantum‐mechanical measurement process, while technical noise was suppressed.…”
Section: Chiral Resolution Np Sensing Approachesmentioning
confidence: 99%
“…The useful signal was amplified by several orders of magnitude by selecting appropriate pre-selected and post-selected states in a quantum-mechanical measurement process, while technical noise was suppressed. Xu et al proposed and demonstrated a novel approach for sensing chiral molecular parameters in glucose, fructose, L-proline, and D-proline solutions by combining the SPR sensing principle with WVA and an associated intensity-modulated mechanism [313]. They used (1) a linearly polarized light beam as the light source to distinguish the chiral molecules, with the optical rotation angle corresponding to the concentration of the chiral molecular solution determined; and (2) an elliptically polarized Gaussian beam as the light source to detect the chiral molecules, with the refractive index corresponding to the concentration of the chiral molecular solution.…”
Section: Nps Based On Surface Plasmon Resonance Sensorsmentioning
confidence: 99%
“…Generally, the kinetic parameters of sucrose hydrolysis are determined by monitoring the optical rotation angle using a polarimeter, with the apparent advantages of real-time and label-free [4]. But the polarimeter requires cumbersome adjustment of polarizers and wave plates during the monitoring process, and its measurement accuracy of the optical rotation angle is less than 10 −3 degree [5], [6]. In order to solve the problem of low measurement accuracy, some methods, such as liquid chromatograph, magnetic resonance imager and Raman spectrometer, have been reported for the determination of kinetic parameters [7]- [10].…”
Section: Introductionmentioning
confidence: 99%
“…From the instrumentation point of view, several efficient methods for the measurement of optical rotatory dispersion spectrum have been reported ( Castiglioni et al, 2011 ; Han et al, 2014 ; Jiang et al, 2017a ; Goldberg and Weissman, 2019 ; Liu et al, 2020 ). Most recently, a novel technique by combining surface plasmon resonance (SPR) and weak value amplification (WVA) was used for high resolution measurements of extremely small optical rotation of chiral molecules in dilute solutions ( Xu et al, 2020 ). In addition to static ORD, several time-resolved ORD experiments have also been demonstrated ( Shapiro et al, 1995 ; Chen et al, 2003 ; Chen et al, 2007 ).…”
Section: Introductionmentioning
confidence: 99%