Measurement of Regional Cerebral Blood Flow With 133 Xenon and a Multiple-Crystal Scintillation Camera

Abstract: Abstract• A method was devised to measure gray and white matter cerebral blood flow simultaneously in multiple regions of the brain using 1S3 Xenon and a multiple-crystal scintillation camera. Following magnification cerebral arteriography, 1S3Xe was injected into the internal carotid artery and the washout of tracer was monitored with a scintillation camera which consists of 294 individually collimated Nal (Tl) crystals. These data, obtained from each crystal overlying the brain, were processed by a weighted … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1976
1976
2000
2000

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 27 publications
0
4
0
Order By: Relevance
“…Moreover, it has been clearly documented that the rCBF of these subcortical areas can increase or decrease by as much as 30% during exercise or movement (13,15,16,58,63,64,73). Because these 133 Xe techniques emphasize the more superficial layers (8,25,47,50,55,59,60), the representation of the MCA distribution by a region detected using these 133 Xe techniques is further eroded.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, it has been clearly documented that the rCBF of these subcortical areas can increase or decrease by as much as 30% during exercise or movement (13,15,16,58,63,64,73). Because these 133 Xe techniques emphasize the more superficial layers (8,25,47,50,55,59,60), the representation of the MCA distribution by a region detected using these 133 Xe techniques is further eroded.…”
Section: Discussionmentioning
confidence: 99%
“…1). The Xe clearance curves and was considered to be the radioactivity shunting through arteriovenous anastomoses or some vascular malformation (Cannon et aL, 1974). In curve peeling, the slope of the middle line is generally determined with the least certainty.…”
Section: Xe Clearancementioning
confidence: 99%
“…With the other two types of analysis this is not so important. The errors otherwise involved have been discussed by Hutten, Schwartz & Wand Schultz (1969 (Cannon, Sciacca, Brust, Johnson & Hilah, 1974). Having once generated this amount of data one must have a system of handling it.…”
Section: )mentioning
confidence: 99%
“…This means that for most commercial gamma cameras the number of regions one can study is quite limited. The multiple crystal scintillation camera however can accommodate a high counting rate and each of the 294 crystals can apparently yield an adequate curve (Cannon, Sciacca, Brust, Johnson & Hilah, 1974). Having once generated this amount of data one must have a system of handling it.…”
Section: Gamma Camera Systemsmentioning