Measurement Uncertainty Calculations for pH Value Obtained by an Ion-Selective Electrode

Abstract: An assessment of measurement uncertainty is a task, which has to be the final step of every chemical assay. Apart from a commonly applied typical assessment method, Monte Carlo (MC) simulations may be used. The simulations are frequently performed by a computer program, which has to be written, and therefore some programming skills are required. It is also possible to use a commonly known spreadsheet and perform such simulations without writing any code. Commercial programs dedicated for the purpose are also a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 23 publications
0
4
0
1
Order By: Relevance
“…The temporal evolution of the CFD and experiment tracer responses was compared (Figure 4), corresponding to the centerline (r = 0 m) of the column at two different axial positions (z = 1.05 and 1.84 m). Although no single uncertainty estimate can be attributed to a pH measurement procedure, it has been shown that the pH measurement uncertainty for commercial glass electrodes is less than 0.05 pH units [34]. All data in Figure 4 were normalized using the highest measurement within a set for ease of comparison.…”
Section: Liquid Phase Dispersion In Single-phase Water Flowmentioning
confidence: 99%
“…The temporal evolution of the CFD and experiment tracer responses was compared (Figure 4), corresponding to the centerline (r = 0 m) of the column at two different axial positions (z = 1.05 and 1.84 m). Although no single uncertainty estimate can be attributed to a pH measurement procedure, it has been shown that the pH measurement uncertainty for commercial glass electrodes is less than 0.05 pH units [34]. All data in Figure 4 were normalized using the highest measurement within a set for ease of comparison.…”
Section: Liquid Phase Dispersion In Single-phase Water Flowmentioning
confidence: 99%
“…Pada pH meter, bahasa pemrograman pada Arduino IDE yang menjadi template standar perlu dilakukan perombakan dikarenakan adanya selisih nilai dengan pH meter digital portable. Sehingga, tim PKM melakukan perombakan program fungsi pembacaan pH dengan mengikuti persamaan berikut dengan buffer pH 4,01 dan 6,89 sebagai acuan standar voltase kalibrasi (EpH4 dan EpH7) (Wiora & Wiora, 2018),…”
Section: Analisis Dan Evaluasiunclassified
“…We have also developed an MS Excel sheet for calculations of unknown concentration and its associated standard deviation according to protocols suggested by Wiora and Wiora. 34 This offered simplicity and automatization of data processing thus further contributing to the notion of suitability of the use of ISPs by non-trained personnel. Figure 5 illustrates the use of digital multimeter as a readout device used to determine salt content in bottled drinking water and instant soup obtained from a local shop.…”
Section: Analytical Characterization and Application Of Ispsmentioning
confidence: 99%