1972
DOI: 10.6028/jres.076a.052
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of absolute values in biochemical fluorescence spectroscopy

Abstract: Fluoresce nce spectroscopy is an important tool of the bioc he mist studyin g th e structure and interac tion s of prote in s and nu cle ic acid s. The four bas ic quantities to measure accurately are: 1. s pec tra (co rrected excitation and e mi ss ion). 2. quantum yields (0), 3. fluoresce nce decay c haracte ri stics, and 4 _ poLarization_ Co mmercially avail ab le instruments, with little modification, can be used to obtain these meas ure me nts, but th e bioc he mi st in this fi eld is ve ry de pende nt on… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
52
0

Year Published

2000
2000
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 85 publications
(53 citation statements)
references
References 41 publications
1
52
0
Order By: Relevance
“…The emission spectra on a wavenumber or energy scale were obtained by multiplying the measured and corrected emission spectra on a wavelength scale with l 2 [61]. The f f values of the DY series, ICG, and FabAntiCEAdDY-676 were calculated from integrated, blank, and spectrally corrected emission spectra (wavelength scale; prior to integration multiplication with l) relative to the standards IR 125 and Oxazine 1 using the following formula [62,63]:…”
Section: Fluorescence Measurementsmentioning
confidence: 99%
“…The emission spectra on a wavenumber or energy scale were obtained by multiplying the measured and corrected emission spectra on a wavelength scale with l 2 [61]. The f f values of the DY series, ICG, and FabAntiCEAdDY-676 were calculated from integrated, blank, and spectrally corrected emission spectra (wavelength scale; prior to integration multiplication with l) relative to the standards IR 125 and Oxazine 1 using the following formula [62,63]:…”
Section: Fluorescence Measurementsmentioning
confidence: 99%
“…7c shows the observed tryptophan spectrum after the signal processing, superimposed with the reference tryptophan spectrum (from ref. 22). The characteristic broad peak of tryptophan fluorescence is clear.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, there exists extensive literature on potential fluorescence standards. This includes for example emission and excitation standards and standards for fluorometric quantities like fluorescence quantum yield, fluorescence lifetime as well as fluorescence (de)polarization [1][2][3][4][14][15]51,52].…”
Section: Types Of Fluorescence Standardsmentioning