2001
DOI: 10.1016/s1352-2310(00)00502-1
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of biogenic VOC emissions: sampling, analysis and calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
50
0
2

Year Published

2002
2002
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(53 citation statements)
references
References 37 publications
1
50
0
2
Order By: Relevance
“…The methods for BVOC chemical detection and calibration, and to some degree sampling systems, have been reviewed recently (Ciccioli et al, 2002;Komenda et al, 2001;Tani et al, 2003;Tholl et al, 2006). In this section, we focus on uncertainties resulting from enclosure types and outline issues relevant for sampling techniques and flux calculations (Sect.…”
Section: Limitations In Estimation Of Emission Factors Due To Samplinmentioning
confidence: 99%
See 2 more Smart Citations
“…The methods for BVOC chemical detection and calibration, and to some degree sampling systems, have been reviewed recently (Ciccioli et al, 2002;Komenda et al, 2001;Tani et al, 2003;Tholl et al, 2006). In this section, we focus on uncertainties resulting from enclosure types and outline issues relevant for sampling techniques and flux calculations (Sect.…”
Section: Limitations In Estimation Of Emission Factors Due To Samplinmentioning
confidence: 99%
“…Komenda et al, 2001 for due consideration of total to projected surface area and dry mass estimations). Details of dry mass, fresh mass and leaf area determination are often lacking.…”
Section: Expression Basis Of E Smentioning
confidence: 99%
See 1 more Smart Citation
“…Raffa and Steffeck (1988) had difficulty quantifying myrcene and they neglected to run any terpenoid derivatives that are also likely to be present in any environmental samples. Another relevant study was published by Komenda et al (2001). They designed a diffusion cell to produce gas-phase standards of various BVOCs including terpenes, oxygenated terpenoids, and aldehydes.…”
Section: L Faiola Et Al: Quantification Of Biogenic Volatile Orgmentioning
confidence: 99%
“…The use of cartridges using Tenax-TA as a sorbent material for measurements of certain BVOC requires significant care (e.g., Helmig, 1997Helmig, , 1999Komenda et al, 2001). On the other hand, with adequate quality control, cartridges can be an excellent way to trap these molecules of interest as they offer a convenient way of sample storage and are easy to use.…”
Section: Theory Of Operationmentioning
confidence: 99%