Measurements of Corneal Thickness in Eyes with Pseudoexfoliation Syndrome: Comparative Study of Different Image Processing Protocols

Abstract: Purpose Comparative analysis of central and peripheral corneal thickness in PEX patients using three different imaging systems: Pentacam-Scheimpflug device, time-domain optical coherence tomography (OCT) Visante, and swept-source OCT Casia. Materials and Methods 128 eyes of 80 patients with diagnosed PEX were examined and compared with 112 normal, non-PEX eyes of 72 cataract patients. The study parameters included 5 measured zones: central and 4 peripheral (superior, inferior, nasal, and temporal). Results The… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 27 publications
0
7
0
Order By: Relevance
“…CCTs measured using the Visante and Casia devices in eyes with pseudoexfoliation syndrome are comparable. 21 …”
Section: Discussionmentioning
confidence: 99%
“…CCTs measured using the Visante and Casia devices in eyes with pseudoexfoliation syndrome are comparable. 21 …”
Section: Discussionmentioning
confidence: 99%
“…Besides, the proposed approach in our study could also realize the quantitative estimation and risk stratification for patients with LUSC and LUAD, promisingly working as an effective and complementary tool to help the clinicians make appropriate treatment decisions. Apart from the current study, development of the quantitative image-based diagnostic models for disease definition has received unprecedented attention these years [2,7,18,25,38,[43][44][45][46][47], not only in the field of cancer diseases, but also in more broad research fields, such as retinal diseases [43,44], diabetes [46], calcaneal fracture [45], and mental disorders [36]. These models have achieved favorable performance in diseases diagnoses and understanding, demonstrating the great power and promising application of these approaches for clinical practice.…”
Section: Table 3 Performance Of the Radiomics-clinical Nomogram In DImentioning
confidence: 93%
“…The primary purpose of both devices is undoubtedly the measurement of intraocular pressure (IOP), the changes of which are the first indicator evidentiary of visual impairment, such as glaucoma or others. However, it is now known that IOP values strongly depend on the central corneal thickness (CCT), age, and in the broad sense, biomechanical parameters of the cornea and the entire eyeball [4349]. Both ORA and Corvis ST in their software contain algorithms allowing to determine the so-called corrected IOP value.…”
Section: Introductionmentioning