Purpose. To report the surgical approach, anatomical and functional results, and complications in the group of patients with corneal perforation. Materials and Methods. 247 eyes with corneal perforation were operated on between January 2010 and July 2016. The three surgical procedures, dependent on size and location of perforation, were performed: full-sized penetrating keratoplasty, corneoscleral patch graft, and anterior lamellar keratoplasty. The eyes underwent the minimum 6-month follow-up visit. Results. Between January 2010 and July 2016, 247 surgeries were performed: 116 penetrating keratoplasties, 117 corneoscleral patch grafts, and 14 anterior lamellar keratoplasties. More than one procedure was necessary in 32 eyes. Final improvement of the visual acuity, within a gain of 2 or more lines with the Snellen test, was achieved in 56 operated eyes. To achieve better final visual acuity, 75 eyes required successive surgical treatment. Complications of the surgery comprised persistent epithelial defect, glaucoma or ocular hypertension, corneal oedema, graft melting, loose corneal sutures, reinfection, anterior synechiae and fibrinoid membranes, and endophthalmitis. In 26 eyes, the treatment failure was reported. Conclusions. There is no one general-purpose surgical technique to treat corneal perforations. The complex nature of this pathology remains the individual, careful but also very distinct and multifactorial approach.
Purpose. To report on surgical approaches using amniotic membrane applications and patch grafts in corneal melting and perforations. Anatomical and functional results, including advantages and disadvantages of the interventions, will also be explored. Methods. A five-year retrospective analysis of 189 surgical treatments involving corneal melting with perforation was performed. In one evaluated treatment type, a graft of amniotic membrane, often folded one to three times, was sutured with the epithelial side facing the previously mechanically debrided corneal tissue. A larger monolayer amniotic patch was then sutured, with the epithelial side facing the top of the first membrane, to the perilimbal conjunctiva. For corneal patch grafts, the size-fitting technique of graft trephination was applied, and the donor-recipient junctions were sewn with interrupted sutures. All the procedures were evaluated, noting outcomes and complications of surgery, preoperative and postoperative visual acuities, postoperative intraocular pressures, graft rejection, and other late comorbidities and complications. Results. We performed 119 amniotic membrane applications (63%) and 70 corneal patch grafts (37%). Anatomical reconstruction of the anterior chamber was achieved in 157 eyes, of which 102 eyes (86%) received an amniotic membrane and 55 eyes (79%) were treated with the patch graft technique. In 63 eyes (33%), more than one amnion or graft treatment was necessary to close the corneal perforation. Conclusions. The success of medical and surgical management depends on the cause of corneal melting, and amniotic membrane applications often require further intervention; nevertheless, patch grafts deliver better tectonic reconstruction than amniotic membrane alone.
Departmental sources Background: Pars plana vitrectomy (PPV) is used to treat retinal conditions, including retinal detachment, and involves removal of the vitreous gel from the eye. Complications following PPV include raised intraocular pressure (IOP). This retrospective study aimed to compare methods of endotamponade used during 23-gauge PPV and the risk of raised IOP during 24-month follow-up at a single center. Material/Methods: The study included 196 patients (age, 15-86 years; mean, 63.5 years) (196 eyeballs). There were 93 patients (47.45%) with a preoperative history of type 2 diabetes mellitus and 14 patients (7.14%) with a history of myopia. IOP was measured with Goldmann applanation tonometry at one-, three-, six-, 12-, and 24-month follow-up. The outcome was compared following endotamponade with silicone oil, sulfur hexafluoride (SF6), and balanced salt solution (BSS). Results: Mean IOP at one-month follow-up was 17.2 mmHg (±3.61 mmHg; range, 9-45 mmHg), and at 24-month follow-up was 17.3 mmHg (±3.23 mmHg; range, 7-30 mmHg). IOP following PPV was significantly associated with the indication for PPV (P=0.023), and the type of endotamponade used (P=0.049). In patients with silicone oil endotamponade, the risk of IOP at 24 months was increased by 2.3 times compared with SF6 or BSS endotamponade. Patients with SF6 endotamponade had a risk of IOP that was 3.3 times lower than for silicone oil tamponade or BSS tamponade. Conclusions: Silicone oil endotamponade in PPV was associated with an increased risk of IOP at 24-month follow-up.
Aims: To evaluate the ocular and systemic factors involved in cataract surgery complications in a teaching hospital using artificial intelligence.Methods: One eye of 1,229 patients with a mean age of 70.2 ± 10.3 years old that underwent cataract surgery was selected for this study. Ocular and systemic details of the patients were recorded and then analyzed by means of artificial intelligence. A total of 1.25 billion simulations of artificial intelligence learning and testing were conducted on several variables and a customized model of analysis was developed.Results: A total of 73 complications were recorded in this study. According to the analysis performed, the main factors involved in cataract surgery complications were: a surgeon in training, axial length and intraocular lens power. The model predicted how long surgery would last with an error of <6 min compared to the effective time needed.Conclusions: According to the data here obtained, artificial intelligence could be an interesting option to build customized models able to prevent complications and to predict actual surgery time. The customized algorithm option allows the development of better models adaptable to different units as well as the possibility to be calibrated for the same unit along time.
Aim. The comparative analysis of the central and peripheral corneal thicknesses using two different imaging systems: Scheimpflug camera and swept-source OCT was performed to investigate the differences in corneal thickness analysis in diabetic patients. Materials and Methods. The study group consisted of the 147 eyes of 107 diabetic patients who were examined and compared with 138 eyes of 89 nondiabetic cataract patients. The inclusion criteria for the study group was diabetes mellitus type II identified no less than 10 years ago, with NPDR not requiring prior laser treatment. The control group was recruited from nondiabetic patients. Measurements were obtained on the Pentacam Scheimpflug imaging system and Casia swept-source OCT. All study parameters from anterior chamber images were processed for five different zones, the central zone and four peripherals—superior, inferior, nasal, and temporal. A fit zone diameter of 4 mm was applied for both instruments. Results. The Pentacam system overestimated corneal measurements in the DM group when compared with the Casia OCT in superior corneal zone (p=0.04), inferior corneal zone (p=0.02), nasal corneal zone (p<0.001), and temporal corneal zone (p=0.01). In the control group, there were also statistically significant differences between the Pentacam and Casia OCT measured values in inferior corneal zone (p=0.001), nasal corneal zone (p=0.04), and temporal corneal zone (p<0.001). Conclusion. Scheimpflug camera pachymetry measurements showed statistically higher CCT values when compared with swept-source OCT measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.