2010
DOI: 10.1088/0953-4075/43/22/225701
|View full text |Cite
|
Sign up to set email alerts
|

Measurements of Mo IS/XBvalues

Abstract: The number of ionization events per photon, i.e. S/XB value, of Mo I lines has been determined by taking a ratio of the sputtered Mo flux, Spt Mo , to the line-of-sight integrated Mo I emission intensity in weakly ionized (ionization degree of ∼1-10%) He plasmas in the linear divertor plasma simulator PISCES-B under the following plasma parameters: electron density n e ∼ (0.6-1.3) × 10 19 m −3 , electron temperature T e ∼ 10-30 eV, ion flux i ∼ (0.9-1.2) × 10 23 m −2 s −1 and incident ion energy to the Mo targ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
1

Year Published

2013
2013
2019
2019

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 21 publications
0
8
1
Order By: Relevance
“…Ref [17]). Hypothesis (ii) is in contradiction with the findings of Ref [19] showing no T e dependence of S/XB for the 386.4 nm MoI line in the T e range of interest. Hypothesis (iii) could not be verified because of lack of the collisional de-excitation cross-section data.…”
Section: Discussion and Summarycontrasting
confidence: 98%
“…Ref [17]). Hypothesis (ii) is in contradiction with the findings of Ref [19] showing no T e dependence of S/XB for the 386.4 nm MoI line in the T e range of interest. Hypothesis (iii) could not be verified because of lack of the collisional de-excitation cross-section data.…”
Section: Discussion and Summarycontrasting
confidence: 98%
“…While the 390nm lines are brightest, the lowest molybdenum reflectivity occurs there 25 , and atomic modeling of the associated ground state transitions is accurate 15 , the low fiber bundle transmission at that range limits the value of these lines for erosion imaging with the present setup. The nearby 410nm lines are much lower intensity, and so also of limited value.…”
Section: Molydenum Line Selectionmentioning
confidence: 93%
“…Experimental investigations using Mo I PFCs have been carried out at Alcator C-Mod [4][5][6]; PISCES-B Mod [7,8]; and the DIII-D tokamak [9]. Furthermore, NSTX-U has plans to install a limited set of molybdenum tiles, with the potential * rsmyth41@qub.ac.uk to upgrade to a fully high-Z wall [10].…”
Section: Introductionmentioning