2017
DOI: 10.4236/jct.2017.813099
|View full text |Cite
|
Sign up to set email alerts
|

Measuring Radiotherapy Setup Errors in IMRT Treated Head and Neck Cancer Patients Requiring Bilateral Neck Irradiation, NCI-Egypt Experience

Abstract: Objective: We aim to quantify the magnitude of setup errors in intensitymodulated radiotherapy (IMRT) treated Head and Neck cancer patients and recommend appropriate PTV margin. Methods: 60 patients with head and neck cancer required bilateral neck irradiation were planned and treated by simultaneous integrated boost IMRT technique either treated radically or postoperative. Patients undergoing image-guided radiotherapy (IGRT) each with once weekly scheduled cone beam computed tomography (CBCT). The 3D displace… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(1 citation statement)
references
References 17 publications
0
1
0
Order By: Relevance
“…Resulting signals are then periodic with a low duty cycle. Modern RT techniques, such as IMRT (intensity-modulated radiation therapy) and VMAT (volumetric-modulated arc therapy) [ 1 , 2 , 3 , 4 ], are oriented towards the delivery of large dose gradients in the shortest time possible. IMRT and VMAT are highly conformal techniques that allow for the irradiation of complex and irregularly shaped tumors close to delicate organs that could be damaged if the absorbed dose exceeds a certain tolerance level; specifically, the dose is released by LINAC in a very short time interval, and is appropriately modulated to be at its maximum on the tumor mass and at its minimum at the level of organs at risk [ 5 , 6 , 7 ].…”
Section: Introductionmentioning
confidence: 99%
“…Resulting signals are then periodic with a low duty cycle. Modern RT techniques, such as IMRT (intensity-modulated radiation therapy) and VMAT (volumetric-modulated arc therapy) [ 1 , 2 , 3 , 4 ], are oriented towards the delivery of large dose gradients in the shortest time possible. IMRT and VMAT are highly conformal techniques that allow for the irradiation of complex and irregularly shaped tumors close to delicate organs that could be damaged if the absorbed dose exceeds a certain tolerance level; specifically, the dose is released by LINAC in a very short time interval, and is appropriately modulated to be at its maximum on the tumor mass and at its minimum at the level of organs at risk [ 5 , 6 , 7 ].…”
Section: Introductionmentioning
confidence: 99%