2008
DOI: 10.1016/j.ajodo.2007.07.017
|View full text |Cite
|
Sign up to set email alerts
|

Mechanical testing and finite element analysis of orthodontic teardrop loop

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
17
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 5 publications
2
17
0
Order By: Relevance
“…This is associated with the longer wire in the inter-bracket space, which promotes both increase in activation amplitude of the loop and reduction of the amount of HF produced. 11,13,15,16,17 Therefore, it was also found that the HF and L/D ratio released by the loops made of SS and BT were greatly influenced by the presence of the helix, resulting in reduction of the mean magnitude of HF by approximately 21% for the SS teardrop-shaped loop, and by 17% for the BT teardrop-shaped loop.…”
Section: Discussionmentioning
confidence: 95%
“…This is associated with the longer wire in the inter-bracket space, which promotes both increase in activation amplitude of the loop and reduction of the amount of HF produced. 11,13,15,16,17 Therefore, it was also found that the HF and L/D ratio released by the loops made of SS and BT were greatly influenced by the presence of the helix, resulting in reduction of the mean magnitude of HF by approximately 21% for the SS teardrop-shaped loop, and by 17% for the BT teardrop-shaped loop.…”
Section: Discussionmentioning
confidence: 95%
“…Finite element analysis used in this study is eminently suited for accurately calculating and optimizing complex loops. 9,10 We used this method to systematically analyze forces and moments at the ends of a ubiquitous type of closing loop. Before discussing the results, it is important to note that forces and moments encountered clinically may differ from the pure loop force system we calculated because they may contain out-of-plane curvature effects or the wire play of a 0.016 3 0.022-inch wire in 0.018 3 0.025-inch bracket slots.…”
Section: Discussionmentioning
confidence: 99%
“…The finite element (FE) method was commonly used to analyze the locations of CR in previous studies 2,[12][13][14][15][16] because of its unique ability to deal with completed biostructures in the clinic. [17][18][19] However, the FE method requires special training and is time consuming, which makes it impractical for use in the clinic.…”
Section: Introductionmentioning
confidence: 99%