RPM 2020
DOI: 10.21926/rpm.2002010
|View full text |Cite
|
Sign up to set email alerts
|

Mechano-Vibrational Spectroscopy of Tissues and Materials Using Vibrational Optical Coherence Tomography: A New Non-Invasive and Non-Destructive Technique

Abstract: Elastic moduli of tissues and synthetic polymeric materials are important design properties needed to develop new implants. In this paper we report the use of vibrational optical coherence tomography (VOCT) to measure the resonant frequency and calculate the modulus of tissues and synthetic polymers non-invasively and non-destructively in vitro and in vivo.Values of tissue and polymer moduli were obtained by applying an audible sinusoidal sound wave to the surface of each specimen. The sound wave travels to th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
79
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(80 citation statements)
references
References 39 publications
1
79
0
Order By: Relevance
“…VOCT is a non-invasive and non-destructive method that uses infrared light and audible sound to create a displacement of skin as described in detail previously. [17][18][19] The measured resonant frequencies are converted into modulus values using a calibration equation (equation 1) developed based on in vitro uniaxial mechanical tensile testing and VOCT measurements. 20,21 Experimentally, the VOCT hand piece uses infrared light to image the specimen as described previously.…”
Section: Vibrational Optical Coherence Tomography (Voct) and Vibratiomentioning
confidence: 99%
See 4 more Smart Citations
“…VOCT is a non-invasive and non-destructive method that uses infrared light and audible sound to create a displacement of skin as described in detail previously. [17][18][19] The measured resonant frequencies are converted into modulus values using a calibration equation (equation 1) developed based on in vitro uniaxial mechanical tensile testing and VOCT measurements. 20,21 Experimentally, the VOCT hand piece uses infrared light to image the specimen as described previously.…”
Section: Vibrational Optical Coherence Tomography (Voct) and Vibratiomentioning
confidence: 99%
“…20,21 Experimentally, the VOCT hand piece uses infrared light to image the specimen as described previously. [17][18][19][20][21] The infrared beam is focused on a fixed position on the area of skin above the tissue to be studied. A frequency generating app is downloaded onto the i5 processor within the VOCT device.…”
Section: Vibrational Optical Coherence Tomography (Voct) and Vibratiomentioning
confidence: 99%
See 3 more Smart Citations