1997
DOI: 10.1159/000201456
|View full text |Cite
|
Sign up to set email alerts
|

Meglumine Gadoterate: A New Safe Radiocontrast Medium for Endoscopic Retrograde Cholangiopancreatography?

Abstract: The radiocontrast substance meglumine gadoterate (MG) is used in magnetic resonance imaging. It is characterized by its low rate of adverse drug reactions. In an open study we tested whether MG is useful in endoscopic retrograde cholangiopancreatography. The patients received in sequence MG and ioxotalamate. MG, in contrast to ioxotalamate, failed to visualize the proximal pancreatic and peripheral intrahepatic ducts. Thus, MG is not useful in routine endoscopic retrograde cholangiopancreatography. However, in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0
3

Year Published

2009
2009
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(24 citation statements)
references
References 4 publications
1
20
0
3
Order By: Relevance
“…Las diferencias en la calidad de imagen descrita en las distintas publicaciones probablemente esté relacionada con la diferente composición química de los compuestos usados, en el estudio de Dorta et al 12 el gadoterato de meglumina contiene 78,6 mg de gadolinio por mililitro de compuesto mientras que el gadobutrol contiene 157,25 mg/ml. La cantidad de contraste utilizada en el procedimiento es similar a la utilizada habitualmente con los contrastes yodados, y la diferencia en la viscosidad del compuesto 4,96 mPas respecto al que utilizamos habitualmente 3 mPas (Iohexol 300 mg/ml diluido 1:1) no supuso ninguna dificultad a la inyección a través de los catéteres.…”
Section: Discussionunclassified
“…Las diferencias en la calidad de imagen descrita en las distintas publicaciones probablemente esté relacionada con la diferente composición química de los compuestos usados, en el estudio de Dorta et al 12 el gadoterato de meglumina contiene 78,6 mg de gadolinio por mililitro de compuesto mientras que el gadobutrol contiene 157,25 mg/ml. La cantidad de contraste utilizada en el procedimiento es similar a la utilizada habitualmente con los contrastes yodados, y la diferencia en la viscosidad del compuesto 4,96 mPas respecto al que utilizamos habitualmente 3 mPas (Iohexol 300 mg/ml diluido 1:1) no supuso ninguna dificultad a la inyección a través de los catéteres.…”
Section: Discussionunclassified
“…His low incidence explains the lack of formal evidence based recommendations.The standard practice recommends prophylaxis, even if data including patients at risk suggest that the use of prophylactic regiments appears to be unnecessary. [14]. Sollte sich die Risikokonstellation erst kurz vor der Untersuchung herausstellen, so verabreichen die 74 % der Endoskopiker Prednison intravenös, die restlichen der befragten Endoskopiker verschieben zur Komplettierung der Prophylaxe die Untersuchung um einen Tag.…”
Section: Spektrum Der Akuten Kontrastmittelreaktionunclassified
“…Until now, in the English literature, 15 cases undergoing ERCP using gadolinium as contrast media have been reported, 1–4 including therapeutic ERCP 3,4 . In these reports, ERCP procedures were successfully carried out withoutadverse reaction.…”
Section: Visualized Structure Of Endoscopic Retrograde Cholangiopancrmentioning
confidence: 99%
“…Adequate visualization of extrahepatic and proximal intrahepatic bile ducts was achieved in 13/14 (93%) of the reported cases (Table 1). However, gadolinium may not be optimum for visualization of pancreatic duct structures 1 …”
Section: Visualized Structure Of Endoscopic Retrograde Cholangiopancrmentioning
confidence: 99%