2021
DOI: 10.1101/2021.01.06.425569
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Metabolite discovery through global annotation of untargeted metabolomics data

Abstract: A primary goal of metabolomics is to identify all biologically important metabolites. One powerful approach is liquid chromatography-high resolution mass spectrometry (LC-MS), yet most LC-MS peaks remain unidentified. Here, we present a global network optimization approach, NetID, to annotate untargeted LC-MS metabolomics data. We consider all experimentally observed ion peaks together, and assign annotations to all of them simultaneously so as to maximize a score that considers properties of peaks (known mass… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 63 publications
0
5
0
Order By: Relevance
“…Among them, 824 metabolites were annotated after MS/MS analysis (~ 25% of total compounds). The annotation rate of human metabolomics analysis is approximately 10% [21,22], suggesting that our annotation rate was reasonable and suitable for further investigations. The annotated compounds are listed in Supplementary le 1.…”
Section: Resultsmentioning
confidence: 65%
“…Among them, 824 metabolites were annotated after MS/MS analysis (~ 25% of total compounds). The annotation rate of human metabolomics analysis is approximately 10% [21,22], suggesting that our annotation rate was reasonable and suitable for further investigations. The annotated compounds are listed in Supplementary le 1.…”
Section: Resultsmentioning
confidence: 65%
“…LC-MS analysis was performed on a Vanquish UHPLC system coupled with an Exploris 480 orbitrap mass spectrometer. LC separation was achieved using a Waters XBridge BEH Amide column (2.1x150mm, 2.5 µm particle size) with a 25-min gradient (Figure S1) [4,22,27]. The retention times of ~600 metabolites using authentic standards are provided in Table S1.…”
Section: Liquid Chromatography-mass Spectrometry (Lc-ms)mentioning
confidence: 99%
“…Source data includes MS/MS spectra of multiple ion forms of both known and unknown molecules, isotopes, adducts, in-source fragments, and multimers. 7,8 The curated reference dataset can be matched in human biospecimens via direct matching of the MS/MS spectra or by sophisticated approaches such as molecular networking. We have created a step-by-step tutorial on how to perform an RDD analysis using the GNPS ecosystem (https://ccms-ucsd.github.io/GNPSDocumentation/tutorials/rdd/).…”
Section: Mainmentioning
confidence: 99%