1979
DOI: 10.1021/ac50050a007
|View full text |Cite
|
Sign up to set email alerts
|

Methionine selective enzyme electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
13
0

Year Published

1982
1982
2011
2011

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(13 citation statements)
references
References 20 publications
0
13
0
Order By: Relevance
“…Fung et al [17] described a potentiometric enzyme electrode prepared with immobilized METase for the assay of L L -methionine. Tanaka et al [18] demonstrated a method of selective determination of L L -methionine and L L -cysteine using METase and they [19] also described the synthesis of D D -a-aminobutyrate using both METase and D D -amino acid aminotransferase.…”
mentioning
confidence: 99%
“…Fung et al [17] described a potentiometric enzyme electrode prepared with immobilized METase for the assay of L L -methionine. Tanaka et al [18] demonstrated a method of selective determination of L L -methionine and L L -cysteine using METase and they [19] also described the synthesis of D D -a-aminobutyrate using both METase and D D -amino acid aminotransferase.…”
mentioning
confidence: 99%
“…Potentiometric gas sensors, particularly the ammonia gas sensor, have become useful analytical detectors for the determination of amino acids and other biomolecules (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11). In these assay systems, various biocatalysts (e.g., enzymes, bacterial cells or tissue slices) are either immobilized on the surface of the gas sensor's membrane (1)(2)(3)(4)(5)(6)(7)(8) or, as in a flowthrough arrangement, the biocatalysts are used in soluble form or are immobilized in a tubular reactor (9)(10)(11). These biocatalysts serve to selectively convert the biomolecule to ammonia (so called "deaminase" enzymes).…”
mentioning
confidence: 99%
“…However, if there is any delay in the analysis of the sample, these background NH3-N levels will greatly increase due to the hydrolysis of blood components into ammonia (14). This increase in NH3-N can interfere with the accuracy of the 1 Present address: Polaroid Corp., 750 Main St., Cambridge, MA 02139. assay. Consequently, physiological samples have to be pretreated by various tedious and time-consuming methods such as cation exchange (11,15) or alkalinization followed by heat evaporation (16,17).…”
mentioning
confidence: 99%
“…An ammonia gas electrode consisting of a combined glass electrode and a gas permeable membrane is usually used for this purpose(ref. 8,9). In this case, the determination must be performed under strong alkaline conditions (above pH 11).…”
Section: Ammonia Sensormentioning
confidence: 99%