2016
DOI: 10.1021/acs.jafc.6b00383
|View full text |Cite
|
Sign up to set email alerts
|

Method Development for the Determination of Free and Esterified Sterols in Button Mushrooms (Agaricus bisporus)

Abstract: Ergosterol is the major sterol in button mushrooms (Agaricus bisporus) and can occur as free alcohol or esterified with fatty acids (ergosteryl esters). In this study, gas chromatography with mass spectrometry in the selected ion monitoring mode (GC/MS-SIM) was used to determine ergosterol and ergosteryl esters as well as other sterols and steryl esters in button mushrooms. Different quality control measures were established and sample preparation procedures were compared to prevent the formation of artifacts … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 35 publications
(23 citation statements)
references
References 43 publications
0
23
0
Order By: Relevance
“…An aliquot of the crude extract (section 2.3) was measured on a 6890/5973 GC/MS system (Agilent Technologies, Santa Clara, CA, USA), equipped with a 30 m HP-5MS column (0.25 mm internal diameter, 0.25 μm film thickness) as recently described in detail [19]. The temperature program started at 55 °C (1 min), was raised with 20 °C/min to 255 °C by 1.5…”
Section: Gas Chromatography With Mass Spectrometry (Gc/ms)mentioning
confidence: 99%
See 1 more Smart Citation
“…An aliquot of the crude extract (section 2.3) was measured on a 6890/5973 GC/MS system (Agilent Technologies, Santa Clara, CA, USA), equipped with a 30 m HP-5MS column (0.25 mm internal diameter, 0.25 μm film thickness) as recently described in detail [19]. The temperature program started at 55 °C (1 min), was raised with 20 °C/min to 255 °C by 1.5…”
Section: Gas Chromatography With Mass Spectrometry (Gc/ms)mentioning
confidence: 99%
“…°C/min to 283 °C and finally by 15 °C/min to 300 °C which was held for 5 min (total run time 35.8 min) [19]. All other GC measurements were performed with a second 6890/5973 GC/MS system equipped with a cool on-column inlet (Hewlett-Packard/Agilent, Waldbronn, Germany), a pre-column (2 m, 0.53 mm i.d., deactivated with 1,3-diphenyl-1,1,3,3tetramethyldisilazane; BGB Analytics, Böckten, Switzerland) and a 15 m, 0.25 mm i.d.…”
Section: Gas Chromatography With Mass Spectrometry (Gc/ms)mentioning
confidence: 99%
“…The steroid compounds found in truffles are involved in the mechanism of tumor protection and angiogenesis [7,23,26,[46][47][48][49][50]. Furthermore, truffles contain stigmasterol and beta-sitosterol, compounds with similar chemical structures to cholesterol.…”
Section: Mass Spectrometry Analysis Of Tuber Magnatum Pico and Tuber mentioning
confidence: 99%
“…The solvent was again removed using nitrogen and taken up in a 5α‐cholestane solution (1 ml; 4 µg/ml, w/v, dissolved in n ‐hexane). GC‐MS analysis was performed via a 6890/5973N GC‐MS system (Agilent) equipped with a HP5‐MS column (30 m × 0.25 mm i.d., 0.25 µm film thickness; Agilent) as described by Hammann and Vetter (2016). The following temperature programme was used: 60°C, raised at 20°C/min to 255°C, at 1.5°C/min to 283°C and finally at 15°C/min to 300°C (held for 5 min), leading to a total run time of 35.6 min.…”
Section: Case Descriptionmentioning
confidence: 99%