2020
DOI: 10.3390/en13040879
|View full text |Cite
|
Sign up to set email alerts
|

Method for Estimating Harmonic Parameters Based on Measurement Data without Phase Angle

Abstract: The excessive use of power electronics makes power quality problems in power grids increasingly prominent. The estimation of the harmonic parameters of harmonic sources in the power grid and the division of harmonic responsibilities are of great significance for the evaluation of power quality. At present, methods for estimating harmonic parameters and harmonic responsibilities need to provide the amplitude and phase information of the current and voltage of the point of common coupling (PCC). However, in prac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 11 publications
0
9
0
Order By: Relevance
“…The decomposition of apparent power under harmonic condition under IEEE Std.1459-2010 is shown in Figure 4. Based on establishment of index set of harmonic economic loss on PCC, economic loss on PCC corresponding to each index can be obtained according to Equations (8) - (13). Therefore, according to Equation (14), total harmonic economic loss on PCC can be determined.…”
Section: A Evaluation Of Total Economic Loss Of Harmonic On Pccmentioning
confidence: 99%
See 1 more Smart Citation
“…The decomposition of apparent power under harmonic condition under IEEE Std.1459-2010 is shown in Figure 4. Based on establishment of index set of harmonic economic loss on PCC, economic loss on PCC corresponding to each index can be obtained according to Equations (8) - (13). Therefore, according to Equation (14), total harmonic economic loss on PCC can be determined.…”
Section: A Evaluation Of Total Economic Loss Of Harmonic On Pccmentioning
confidence: 99%
“…Subsequently, this method has been widely used. Based on it, the literature [10][11][12][13] carry out indepth research on calculation of harmonic impedance of utility side, but it in fact uses traditional method based on superposition projection principle to calculate harmonic responsibility quantitatively, which does not effectively innovate quantitative calculation method of harmonic responsibility. The literature [14] carries out research on quantitative calculation method of harmonic responsibility based on the principle of superimposed projection, which realizes harmonic source can be divided into two kinds, one kind is augmentation harmonic source, the other kind is subtraction harmonic source.…”
Section: Introductionmentioning
confidence: 99%
“…The work by F.L. Zhou et al [13], "Method for Estimating Harmonic Parameters Based on Measurement Data without Phase Angle", proposed a method for estimating harmonic parameters in the case of monitoring data without phase, based on the partial least square regression method. The proposed method utilized the amplitude information of the harmonic voltage and current of the point of common coupling to estimate the harmonic parameters and the harmonic responsibility of each harmonic source.…”
Section: Brief Overview Of the Contributionsmentioning
confidence: 99%
“…Then, using large amounts of measured harmonic data, they calculate the harmonic impedance and harmonic emission level by regression estimation. Moreover, [20] proposed a method to estimate harmonic parameters and harmonic responsibility with the harmonic amplitude and phase difference of harmonic voltage and current. These methods have already had quite mature applications in the UPG, so in these research works it is possible to use the linear regression method in RESs.…”
Section: Introductionmentioning
confidence: 99%