2017
DOI: 10.1117/12.2280974
|View full text |Cite
|
Sign up to set email alerts
|

Method of magneto-elastic control of mechanic rigidity in assemblies of hydropower units

Abstract: Paper abstract. Developed was a new method of control of mechanic rigidity in assemblies of hydropower units that allows a real-time control of technological process, and proposed was the design for a primary measuring transducer of mechanic intensity as a component of the control method proposed, with its transformation equations obtained.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…For the set measuring range ( Figure 7 ) and the standard deviation of the quantization error for (24), the amount of information of the measuring channel of optical intensity is bits. This result does not contradict the empirical methods for determining the bit size of the analog-to-digital converter [ 40 , 47 , 49 , 50 ].…”
Section: Transmission and Evaluation Of The Measuring Information Amountmentioning
confidence: 60%
See 1 more Smart Citation
“…For the set measuring range ( Figure 7 ) and the standard deviation of the quantization error for (24), the amount of information of the measuring channel of optical intensity is bits. This result does not contradict the empirical methods for determining the bit size of the analog-to-digital converter [ 40 , 47 , 49 , 50 ].…”
Section: Transmission and Evaluation Of The Measuring Information Amountmentioning
confidence: 60%
“…The solution of the last equation is obtained by K . Shannon and has the following final form [ 47 , 49 , 50 ].…”
Section: Transmission and Evaluation Of The Measuring Information Amountmentioning
confidence: 99%
“…1. The absorption of the main components of flue gases of boiler installations in the range of 4-4.5 microns (2200-2500 cm -1 ) is presented [5,8,16].…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, the necessary condition is not only the choice of the lengths of absorption of gases in such a way that they are not superimposed on each other, but also to use high-precision radiation sources and receivers (whose breadth of spectrum does not allow the "adjacent" gases to enter). After analysing the lengths of absorption of flue gases, it is necessary to select infrared emitters and receivers according to already known input data [6,7].…”
Section: Methodsmentioning
confidence: 99%
“…Exploring equation (6) for a case where the volume of fluid flowing through the vavle pulser exceeds the volume of fluid supplied during this time by the hydraulic pump, ie when W h <W V or Qh<Q V . Moreover, Qh<[Q V ], where [Q V ]the marginal consumption that can pass through the valve pulser through itself, providing on the confluenting the pressure of the working fluid that does not exceed the value p. Taking into account the accepted assumption [13,14]: (8) We substitute equation (8) into equation (7) and introduce a substitution: (9) .…”
Section: Analytical Substantiation Of the Existence Of Non-stop Periomentioning
confidence: 99%