“…We implemented the calibration strategy based on a quarter wave plate following a standard calibration method 39 . We rotated the fast axis of the quarter wave plate from 0 deg to 180 deg with a 10-deg increment and acquired a set of four hyperspectral data cubes at each step.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…We implemented the calibration strategy based on a quarter wave plate following a standard calibration method 39 . We rotated the fast axis of the quarter wave plate from 0 deg to 180 deg with a 10-deg increment and acquired a set of four hyperspectral data cubes at each step.…”
Section: Methodsmentioning
confidence: 99%
“…We implemented the calibration strategy based on a quarter wave plate following a standard calibration method. 39 We rotated the fast axis of the quarter wave plate from 0 deg to 180 deg with a 10-deg increment and acquired a set of four hyperspectral data cubes at each step. The theoretical relationships between the Stokes vector parameters ( , , and ) normalized by and fast axis positions ( ) are shown in Eq.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, fullStokes polarization can be achieved by multiple measurements in the time domain. For example, rotating retarders [18], liquid crystal retarders [19][20][21][22][23], piezo optic modulators [24] or the electrooptic modulators [25] were used in combination with a normal image sensor, cap turing different four polarization images in DoT polarimeters. Nevertheless, the mechanical rotation and nematic LCVR are too slow, and the piezooptic and optic modulators are too fast for imaging, high speed fullStokes imaging for moving objects keeps as a challenge so far.…”
mentioning
confidence: 99%
“…Apart from these, several types of polarimetric calibrations have been derived over the years [6], including those related to a solution for a particular system [83,[110][111][112][113][114], a specific calibration method to partially Stokes polarimetry [95,115], or both features such as DoFP microgrid cameras [116,117]. Among them, three main methods can be highlighted whose principal advantage is the system-independent procedure: Data Reduction Matrix method (DRM) [118], and Eigenvalue Calibration Method (ECM) [119], and the recently Polarizer Calibration Method (PCM) [120].…”
Section: Polarimetric Calibrationmentioning
confidence: 99%