Method to secure the performance of the differential protection in presence of fault current limiter applied into the neutral line

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
11
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 18 publications
1
11
0
Order By: Relevance
“…In previous studies, powerful and well‐known techniques based on the variation rate of the current waveform are proposed to identify the distorted waveform. These methods were founded on this fact that derivatives of a sinusoidal signal for 2 consecutive samples are almost equal.…”
Section: The Proposed Algorithmmentioning
confidence: 99%
“…In previous studies, powerful and well‐known techniques based on the variation rate of the current waveform are proposed to identify the distorted waveform. These methods were founded on this fact that derivatives of a sinusoidal signal for 2 consecutive samples are almost equal.…”
Section: The Proposed Algorithmmentioning
confidence: 99%
“…On the other hand, in order to handle the increased fault current, protection equipment such as fuses and breakers should be replaced with higher rating equipment, which is a time consuming and expensive approach. Utilizing fault current limiters (FCLs) is one of the most attractive techniques to overcome these problems . During normal operation of power system, these facilities have negligible effect on the power system.…”
Section: Introductionmentioning
confidence: 99%
“…Utilizing fault current limiters (FCLs) is one of the most attractive techniques to overcome these problems. [8][9][10][11][12][13][14][15] During normal operation of power system, these facilities have negligible effect on the power system. However, they limit fault current through an impedance when a fault occurs.…”
Section: Introductionmentioning
confidence: 99%
“…The analysis of the impacts of SFCL on the power system and vice versa, the impact of the power system parameters on SFCL performance are the important aspects of these evaluations. Albeit, it has been performed meritorious studies in both terms, [15][16][17][18][19][20][21][22][23] but in the second term, 1 of the fields that have been less considered in the previous studies is the effect of fault resistance and the position of fault on the fault current reduction ratio (FCRR) of SFCL. FCRR is defined as the ability of SFCL to limit the fault current.…”
Section: Introductionmentioning
confidence: 99%