2018
DOI: 10.3390/en11051240
|View full text |Cite
|
Sign up to set email alerts
|

Methodology and a Continuous Time Mathematical Model for Selecting the Optimum Capacity of a Heat Accumulator Integrated with a CHP Plant

Abstract: This paper contains the results of a study in which a novel approach using continuous time notation was applied in the search for the optimum capacity of a heat accumulation tank to be combined with an existing CHP (combined heat and power) plant. The necessary condition associated with the economic profitability of the application of heat accumulation tanks in CHP plants is based on the condition that the profit from the exploitation of the modernized CHP plant does not decrease in relation to this profit bef… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
4

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Continuous time notations have a considerable advantage over discrete records [10]. They make it possible to easily and quickly analyze variations in, for example, the value of NPV (net present value) in order to find its optimal value [11]. In addition, these notations provide means for the analysis of variations in this value depending on changes in time, among others in energy prices and environmental charges [12].…”
Section: Mathematical Models Applying Continuous Time Notation In Tec...mentioning
confidence: 99%
“…Continuous time notations have a considerable advantage over discrete records [10]. They make it possible to easily and quickly analyze variations in, for example, the value of NPV (net present value) in order to find its optimal value [11]. In addition, these notations provide means for the analysis of variations in this value depending on changes in time, among others in energy prices and environmental charges [12].…”
Section: Mathematical Models Applying Continuous Time Notation In Tec...mentioning
confidence: 99%
“…In the literature in this area, existing reports usually focus on combined gas and steam mono-fuel systems, also so-called CCPP [2][3][4][5]. A small number of works relate to the dual-fuel gas-steam system and only deal with a few specific cases of parallel and serial connection of a gas turbine with a steam turbine [1,[6][7][8][9][10][11][12][13][14][15][16][17][18]. These works only deal with selected manner in which the Joule cycle with the Clausius-Rankine cycle can be coupled, among many possible ways.…”
Section: Methodology Of Technical and Economic Analysis Of Dual-fuel mentioning
confidence: 99%
“…They are presented below using graphs developed by the method that is generally recognized in the literature in the field [18,[23][24][25][26].…”
Section: Energy Balances Of Dual-fuel Gas-steam Chp Plants In a Paralmentioning
confidence: 99%
“…In the classical SOFC, steam is generated directly by the electrochemical processes at the anode, while in an H+SOFC steam is generated at the cathode, excluding any option of the cell being fed pure hydrocarbon fuel. This gives a potential application for hydrogen based energy storage systems [27][28][29] which can be combined with thermal energy storage [29][30][31][32] as an alternative to other energy storage technologies [33][34][35]. Sourcing hydrogen is currently done mainly through the steam reforming of methane, which does not readily lend itself to inclusion in renewable technology sys- tems.…”
Section: Introductionmentioning
confidence: 99%