Medical Imaging 2001: Physics of Medical Imaging 2001
DOI: 10.1117/12.430859
|View full text |Cite
|
Sign up to set email alerts
|

Methodology to measure fundamental performance parameters of x-ray detectors

Abstract: To judge the potential benefit of a new x-ray detector technology and to be able to compare different technologies, some standard performance measurements must be defined. In addition to technology-related parameters which may influence weight, shape, image distortions and readout speed, there are fundamental performance parameters which directly influence the achievable image quality and dose efficiency of x-ray detectors. A standardization activity for detective quantum efficiency (DQE) for static detectors … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2005
2005
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(17 citation statements)
references
References 9 publications
0
17
0
Order By: Relevance
“…Due to the high resistivity of PbO, the dark current shot noise contributes only 300 electrons/pixel to the pixel noise. All noise power spectra were corrected for lag effects [17].…”
Section: Large Plates: Imaging Performancementioning
confidence: 99%
“…Due to the high resistivity of PbO, the dark current shot noise contributes only 300 electrons/pixel to the pixel noise. All noise power spectra were corrected for lag effects [17].…”
Section: Large Plates: Imaging Performancementioning
confidence: 99%
“…The results of their studies were dependent on the subjective performance of observers using a contrast-detail method to evaluate the relationship between contrast resolution and dose. Busse et al (2001) provided a quantitative discussion of various system noise sources in dynamic imaging detectors and developed metrics to compare detector technologies based on signal and electronic noise levels and their impact on DQE. In later years, studies on indirect flat-panel detectors (Roos et al 2004) have used the fact that the detector x-ray entrance exposure at which the instrumentation noise and the quantum noise are equal has an SNR that was reduced by a factor of 2 due to the instrumentation noise.…”
Section: Introductionmentioning
confidence: 99%
“…For both measurements, proper gain calibration and compensation of low-frequency drop effects by means of deconvolution was required in order to produce reasonably accurate results using this procedure. Determination of the low-frequency drop characteristics was carried out using a technique based on lead disc measurements 21 .…”
Section: Test Bench Experimentsmentioning
confidence: 99%