Metrological traceability of oceanographic salinity measurement results

Abstract: Abstract. Consistency of observed oceanographic salinity data is discussed with respect to contemporary metrological concepts. The claimed small uncertainty of salinity measurement results traceable to the conductivity ratio of a certified IAPSO Standard Seawater reference is not metrologically justified if results are compared on climatic time scales. This applies in particular to Practical Salinity S P , Reference Salinity S R , and the latest estimates of Absolute Salinity using the TEOS-10 formalism. On cl… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 36 publications
0
16
0
Order By: Relevance
“…Such links may consist of equations (or “conventions”), such as the TEOS-10 equation for the density of standard seawater which permits the calculation of Absolute Salinity from measurements of temperature, pressure and density, all of the latter traceable to the SI (Seitz et al, 2011). A similar approach is possible for the relative fugacity making use of the TEOS-10 equation of state of humid air (Feistel, 2012; Feistel et al, 2015).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Such links may consist of equations (or “conventions”), such as the TEOS-10 equation for the density of standard seawater which permits the calculation of Absolute Salinity from measurements of temperature, pressure and density, all of the latter traceable to the SI (Seitz et al, 2011). A similar approach is possible for the relative fugacity making use of the TEOS-10 equation of state of humid air (Feistel, 2012; Feistel et al, 2015).…”
Section: Discussionmentioning
confidence: 99%
“…An uncertainty level of 0.002 g kg −1 in dissolved mass fraction (i.e., a relative uncertainty of 6 × 10 −5 for typical seawater with a dissolved mass fraction of about 35 g kg −1 ) is required for routine research and monitoring purposes (SUN, 1985; Seitz et al, 2011). Significant efforts have been made to ensure consistency of salinity measurements to this level over the past century; unfortunately, no robust link has yet been established between any of the salinity definitions and the International System of Units (SI) despite the fact that Practical Salinity was recommended for oceanography in the context of SI units (SUN, 1985; Siedler, 1998).…”
Section: Seawater Salinitymentioning
confidence: 99%
See 1 more Smart Citation
“…IAPSO Standard Seawater is used as a primary standard for the conductivity calibration (Seitz et al, 2011;Integrated Ocean Observing System, 2016). The practical salinity of IAPSO is obtained by a series of conductance measurements at OSIL relative to KCL standard solutions, prepared using precise weights of KCL crystals (Bacon et al, 2007).…”
Section: Conductivity and Sea Water Temperaturementioning
confidence: 99%
“…However, a widely accepted international standard for temperature does exist -the International Temperature Scale of 1990(ITS-90, Preston-Thomas, 1990)and the technical effort required in maintaining this standard occurs outside the oceanographic community. More problematic is the fact that absolute measurements of electrical conductivity, traceable to the seven base units of the International System of Units (SI), can still not be made accurately enough to support the needs of oceanographers (Seitz et al, 2011). Physical oceanographers must then grapple with fundamental measurement issues in a way that does not occur in (and is not easily appreciated by) other areas of earth science.…”
Section: Introductionmentioning