2020
DOI: 10.1016/j.optlastec.2020.106296
|View full text |Cite
|
Sign up to set email alerts
|

Microfiber Fabry-Perot interferometer used as a temperature sensor and an optical modulator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(11 citation statements)
references
References 21 publications
0
11
0
Order By: Relevance
“…The temperature sensitivity of the proposed sensor is the highest when compared to other sensors. Among them, compared to the sensor proposed in [4,8,38], the sensor we proposed has higher sensitivity and occupies a smaller bandwidth. The measurement range of the proposed sensor is smaller than the sensor proposed in [4,38,39], but we can change the design parameters to expand the measurement range, and this is at the expense of sensitivity.…”
Section: Experiments and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The temperature sensitivity of the proposed sensor is the highest when compared to other sensors. Among them, compared to the sensor proposed in [4,8,38], the sensor we proposed has higher sensitivity and occupies a smaller bandwidth. The measurement range of the proposed sensor is smaller than the sensor proposed in [4,38,39], but we can change the design parameters to expand the measurement range, and this is at the expense of sensitivity.…”
Section: Experiments and Discussionmentioning
confidence: 99%
“…Among them, compared to the sensor proposed in [4,8,38], the sensor we proposed has higher sensitivity and occupies a smaller bandwidth. The measurement range of the proposed sensor is smaller than the sensor proposed in [4,38,39], but we can change the design parameters to expand the measurement range, and this is at the expense of sensitivity. To further improve the sensitivity of the Vernier effect, a light source with a larger bandwidth and a higher resolution device are required.…”
Section: Experiments and Discussionmentioning
confidence: 99%
“…Furthermore, the work with SMF fiber attached to the sensing head with a diameter of 32 mm x 16 mm, which is much bigger than fibers, can make it difficult to keep the stability of the measurement process. The slightly different variant of the construction is presented by Li et al [110] Authors aligned SMF and microfiber inside the capillary filled with PDMS. As above they obtain in-line FPI due to the reflection of light by the boundaries SMF/PDMS and PDMS/microfiber.…”
Section: In-line Pof Fpi For Temperature Sensingmentioning
confidence: 99%
“…This paper proposes a cascaded FPIs vernier effect temperature sensor, which uses polydimethylsiloxane (PDMS) as the heat-sensitive medium and few mode fiber (FMF) is used as the transmission medium. Due to the good thermal sensitivity of PDMS [13], the thermal sensitivity of this sensor is greatly improved compared with the traditional all-fiber F-P sensors. Compared with MMF and SMF, FMF can hold no more than ten modes.…”
Section: Introductionmentioning
confidence: 99%