2018
DOI: 10.1002/dta.2515
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids

Abstract: Quick but accurate testing and on-the-spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut-off levels are required. With respect to surface water, the presence of anthropogenic small organic molecule… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
26
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 36 publications
(26 citation statements)
references
References 38 publications
0
26
0
Order By: Relevance
“…As shown in Table 2, most of the developed biosensors are able to detect cocaine in trace concentration and in a wide range of sample matrices (mostly biological samples). Recently, sub µM limit of detection has been achieved by using bioderived [55,56,59] or hybrid nanozyme receptors [53]. However, the nanoMIPs used in this work guarantees higher stability against environmental factors that usually affect bioderived receptors (protein, antibodies and aptamers), such as high or low temperatures and enzymatic degradation.…”
Section: Sensor Sensitivity and Specificitymentioning
confidence: 99%
“…As shown in Table 2, most of the developed biosensors are able to detect cocaine in trace concentration and in a wide range of sample matrices (mostly biological samples). Recently, sub µM limit of detection has been achieved by using bioderived [55,56,59] or hybrid nanozyme receptors [53]. However, the nanoMIPs used in this work guarantees higher stability against environmental factors that usually affect bioderived receptors (protein, antibodies and aptamers), such as high or low temperatures and enzymatic degradation.…”
Section: Sensor Sensitivity and Specificitymentioning
confidence: 99%
“…However, when cocaine is present, the negatively charged AuNPs approach the electrode surface, which results in inhibited electron transfer and the redox probe current decreases [ 59 ]. Even the most recent immunosensor for cocaine biosensing (0.49 nM [ 60 ]) is not able to compete with the LOD of 100 pM exhibited by the presented aptasensor. This drastic improvement of LOD over the past years highlights the high versatility of aptasensing technology.…”
Section: Comparison Of Aptasensors and Immunosensors For Small Molmentioning
confidence: 99%
“…Some scientists found a way to merge the ELISA principle with SPEs in order to construct a hybrid microfluidic sensor capable of detect traces of cocaine in water and body fluids [ 67 ]. New and improved diagnosis methods can also be obtained by combining molecular techniques for the amplification of specific sequences and functionalized screen-printed electrodes to detect the amplified product.…”
Section: Evaluation Of the Performance Of Spe-based Sensors Versusmentioning
confidence: 99%