2017
DOI: 10.1016/j.tibtech.2017.07.008
|View full text |Cite
|
Sign up to set email alerts
|

Microfluidics for Combating Antimicrobial Resistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
35
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(35 citation statements)
references
References 59 publications
0
35
0
Order By: Relevance
“…The red colour intensity increased with time (Figure 4a), and the colour intensity levels variability was found to be 5% (%RSD) between the 15 microchannels and 9% (%RSD) between the microchips (n = 3). Figure 4c shows the graph of colour intensity change at different times (3,6,12,18,24,30, 60 and 120 s) for the 15 microchannels in a single microchip. Biosensors 2020, 10, x FOR PEER REVIEW 5 of 8 Furthermore, the presence of β-lactamase, an indicator of antimicrobial resistance [23,24] was tested by dipping nitrocefin-coated microchannels into a β-lactamase solution (Abcam, recombinant Escherichia coli β-lactamase protein) and DI water samples.…”
Section: Characterization Of Reagent Cross-linking Inside the Microchmentioning
confidence: 99%
See 2 more Smart Citations
“…The red colour intensity increased with time (Figure 4a), and the colour intensity levels variability was found to be 5% (%RSD) between the 15 microchannels and 9% (%RSD) between the microchips (n = 3). Figure 4c shows the graph of colour intensity change at different times (3,6,12,18,24,30, 60 and 120 s) for the 15 microchannels in a single microchip. Biosensors 2020, 10, x FOR PEER REVIEW 5 of 8 Furthermore, the presence of β-lactamase, an indicator of antimicrobial resistance [23,24] was tested by dipping nitrocefin-coated microchannels into a β-lactamase solution (Abcam, recombinant Escherichia coli β-lactamase protein) and DI water samples.…”
Section: Characterization Of Reagent Cross-linking Inside the Microchmentioning
confidence: 99%
“…The red colour intensity increased with time ( Figure 4a), and the colour intensity levels variability was found to be 5% (%RSD) between the 15 microchannels and 9% (%RSD) between the microchips (n = 3). Figure 4c shows the graph of colour intensity change at different times (3,6,12,18,24,30, 60 and 120 s) for the 15 microchannels in a single microchip. A smartphone (iPhone XR) was used to capture images of the microchip under external light, which could add variations in the light signal of the different microchannels.…”
Section: Characterization Of Reagent Cross-linking Inside the Microchmentioning
confidence: 99%
See 1 more Smart Citation
“…This information regarding the persister cells can help in the development of the new strategies for the treatment of such diseases. Micro luidic systems have also been effectively used in the screening of the individual bacterial cell for the formation of some precise chemicals and the biomechanical characteristics which might be associated with the AMR and cannot be possible using the current methods (Liu et al, 2017).…”
Section: To Get To Know More About Bacteriamentioning
confidence: 99%
“…The outlook of the POC devices is to provide quick analysis which can lead towards the quicker clinical decisions and hence allow the early start of treatments for patients. These earlier well-informed treatments will have better chances to improve the health of the patients as compared to the less-informed treatments while waiting for the central lab results [4,5].…”
Section: Introductionmentioning
confidence: 99%