2010
DOI: 10.1111/j.1745-4530.2009.00565.x
|View full text |Cite
|
Sign up to set email alerts
|

Microstructural Characterization of Deep‐fat Fried Breaded Chicken Nuggets Using X‐ray Micro‐computed Tomography

Abstract: X‐ray micro‐computed tomography imaging technique was applied to study microstructural characteristics of deep‐fat fried chicken nuggets. The results obtained showed a significant (P < 0.05) influence of frying conditions on microstructural properties of the deep‐fat fried breaded chicken nuggets. The porosity of the breading coating increased while that of the core remained relatively unchanged with frying time. The number of pores also increased with frying. The chicken nuggets coating and core pores showed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 32 publications
(9 citation statements)
references
References 29 publications
1
8
0
Order By: Relevance
“…Using regression equations describing the relationship between porosity and moisture content at the temperature utilized in this study , a crude porosity calculation of 34% is obtained for undipped control fritters and 29% for the egg‐dipped reduced fat fritters, a 14% decline in porosity corresponding to a 16% increase in moisture. These porosity values are in the range for chicken nuggets reported previously . While valuable as a theoretical tool, the utility of calculated porosity values is suspect in light of the fact that the same regression equations describing the relationship between porosity and lipid content produced negative porosity values, suggesting decreased pore size.…”
Section: Resultssupporting
confidence: 50%
See 1 more Smart Citation
“…Using regression equations describing the relationship between porosity and moisture content at the temperature utilized in this study , a crude porosity calculation of 34% is obtained for undipped control fritters and 29% for the egg‐dipped reduced fat fritters, a 14% decline in porosity corresponding to a 16% increase in moisture. These porosity values are in the range for chicken nuggets reported previously . While valuable as a theoretical tool, the utility of calculated porosity values is suspect in light of the fact that the same regression equations describing the relationship between porosity and lipid content produced negative porosity values, suggesting decreased pore size.…”
Section: Resultssupporting
confidence: 50%
“…This group reports that porosity values are dependent on the method of measurement. For example, porosity in chicken nuggets ranged from 39 to 69% using mercury intrusion porisometry , 7 to 14% using X‐ray microcomputed tomography , 2 to 48% using a pycnometer method , and 4 to 32% using confocal laser scanning microscopy . These studies also show a positive correlation between porosity and moisture content and a negative correlation between porosity and oil content and report that the newly created pores are either very small or very large compared to the distribution of pore sizes in the unfried samples.…”
Section: Resultsmentioning
confidence: 91%
“…Mass transport Eqs and include volume fraction of fluids as dependent variable. Initial gas volume fraction was chosen to be 0.06 (Adedeji and Ngadi ). Initial volume fractions values can be obtained from initial mass fractions using the following relations truerightWw=leftρwɛwρs(1ɛwɛoɛg)0.16em and rightWo=leftρoɛoρs(1ɛwɛoɛg)…”
Section: Simulations—transport Phenomena In Chicken Nuggets During Frmentioning
confidence: 99%
“…The attenuated energy that passed through the object is detected using a photodetector, a film, or an ionization chamber on the other side. The attenuation coefficients of the object components lead to different contrast between such components [69][70][71]. Computed Tomography (CT) X-ray imaging is a more recent and advanced technique than plain X-ray technology.…”
Section: X-ray Imagingmentioning
confidence: 99%