“…10 kHz) in order to avoid cross-talking disturbances between the two signals. The instrumental details have been described elsewhere [14,15]. The probes used for the KFM were Nanoprobes SPM probes of SCM-PIT type purchased from Bruker, with the length of 200-250 µm, a resonance frequency of 60-100 kHz, a spring constant of 1-5 N/m and with a conducting coating (Pt-Ir) necessary for the electrical measurement.…”
Section: Kfm Measurementsmentioning
confidence: 99%
“…10 kHz) in order to avoid cross-talking disturbances between the two signals. The instrumental details have been described elsewhere [14,15]. The probes used for the KFM were Nanoprobes SPM probes of SCM-PIT type purchased from Bruker, with the length of 200-250 µm, a resonance frequency of 60-100 kHz, a spring constant of 1-5 N/m and with a conducting coating (Pt-Ir) necessary for the electrical measurement.…”
Section: Kfm Measurementsmentioning
confidence: 99%
“…2b, obtained from the KFM measurement, shows that the nitride particles have a higher Volta potential than the alloy matrix. Furthermore, those darker nitride particles (enriched in vanadium and nitrogen) exhibit higher Volta potential in the SEM image than lighter nitride particles, as reported previously [25]. Thus, it would be expected that under corrosive conditions the different nitride particles would likely show a different tendency to corrosion.…”
Section: Microstructure and Corrosion Tendencymentioning
confidence: 53%
“…An earlier study showed that pitting can initiate and develop in these matrix areas under accelerated conditions in a similar NaCl solution [25]. However the height images show that the small features (size range tens of nanometres) protrude from the surface and cannot thus be considered as pitting phenomena per se.…”
Section: Pre-pitting Eventsmentioning
confidence: 96%
See 1 more Smart Citation
“…[16,17] In particular, in Reference 17, the correlation between the corrosion resistance and structure of the Fe-20pctCr-9pctV-4pctN alloy prepared by powder metallurgy was investigated. This alloy exhibits the improved corrosive behavior as compared to that of commercial high-carbon steel Elmax.…”