2009
DOI: 10.3390/s90806232
|View full text |Cite
|
Sign up to set email alerts
|

Mid-Infrared Sensing of Organic Pollutants in Aqueous Environments

Abstract: The development of chemical sensors for monitoring the levels of organic pollutants in the aquatic environment has received a great deal of attention in recent decades. In particular, the mid-infrared (MIR) sensor based on attenuated total reflectance (ATR) is a promising analytical tool that has been used to detect a variety of hydrocarbon compounds (i.e., aromatics, alkyl halides, phenols, etc.) dissolved in water. It has been shown that under certain conditions the MIR-ATR sensor is capable of achieving det… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
41
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 55 publications
(42 citation statements)
references
References 57 publications
1
41
0
Order By: Relevance
“…5a, a film thickness of 8.4 lm was chosen for further studies since it displayed the most optimum analytical performance in terms of sensitivity and reproducibility. Various reports recommend that the film thickness needs to be approximately three times the infrared penetration depth to ensure optimum performance (Pejcic et al, 2009b;Lin and Li, 2010). Fig.…”
Section: Moleculementioning
confidence: 99%
See 1 more Smart Citation
“…5a, a film thickness of 8.4 lm was chosen for further studies since it displayed the most optimum analytical performance in terms of sensitivity and reproducibility. Various reports recommend that the film thickness needs to be approximately three times the infrared penetration depth to ensure optimum performance (Pejcic et al, 2009b;Lin and Li, 2010). Fig.…”
Section: Moleculementioning
confidence: 99%
“…http://dx.doi.org/10.1016/j.orggeochem.2012.11.011 and quantification in geochemical fluids (Mizaikoff, 2003;Pejcic et al, 2009b;Gonzalvez et al, 2011). Due to its inherent selectivity the ATR-FTIR has been successfully used to detect a wide variety of organic compounds such as phenols (Yang and Cheng, 2001), caffeine (Alcudia-Leon et al, 2008), organophosphonates (Bryant et al, 2007), adamantane , alkyl halides (Acha et al, 2000;Yang and Ramesh, 2005), aromatic hydrocarbons (Karlowatz et al, 2004;Pejcic et al, 2009a;Young et al, 2011), and for the detection of oil-in-water as well as water-in-oil (Luzinova et al, 2012a,b).…”
Section: Introductionmentioning
confidence: 99%
“…Attenuated total reflection (ATR)-IR sensors have been used to measure traces of organic compounds in water, mainly for environmental applications [35][36][37][38][39][40][41][42][43]. These systems employ a thin polymer film [38,[40][41][42] or sol gel layer [39,43] to absorb organic compounds, concentrating the analyte in the evanescence sensing region, and enabling limits of detection in the low ppm and in some cases ppb range.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7][8] To achieve a universal mid-IR platform, the material requires broad mid-IR transparency, high nonlinearity, and the ability to be employed by very-large-scale integration (VLSI) processes. However, there is an urgent demand to move current microphotonics toward the mid-IR spectrum because it will not only increase the bandwidth of current optoelectronics but will also enable high throughput screening for on-chip spectroscopic sensing.…”
Section: Introductionmentioning
confidence: 99%