1997
DOI: 10.1063/1.1148059
|View full text |Cite
|
Sign up to set email alerts
|

Miniature microwave powered steam sterilization chamber

Abstract: A small device for the rapid ultrahigh temperature sterilization of surfaces is described. Microwave power generated by a 2.45 GHz magnetron is delivered via coaxial cable to a silicon carbide block housed within the chamber. Small quantities of water or aqueous hydrogen peroxide are introduced into the chamber. Upon application of power, the liquid flashes to vapor and superheats producing temperatures to 300 °C. The hot vapor permeates the enclosed space and contacts all exposed surfaces. Complete microbial … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2001
2001
2015
2015

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…Sodium hypochlorite disinfection has been well (7,13,22,(25)(26)(27)(28)38). Steam treatment is also a well-known method for inactivating viruses on surfaces (6,14,16,26,31). However, typical steam sterilization requires the use of an autoclave which utilizes pressurized steam at 121°C, which was shown previously to have a deleterious effect on FFR performance (36).…”
Section: Discussionmentioning
confidence: 99%
“…Sodium hypochlorite disinfection has been well (7,13,22,(25)(26)(27)(28)38). Steam treatment is also a well-known method for inactivating viruses on surfaces (6,14,16,26,31). However, typical steam sterilization requires the use of an autoclave which utilizes pressurized steam at 121°C, which was shown previously to have a deleterious effect on FFR performance (36).…”
Section: Discussionmentioning
confidence: 99%
“…The use of microwave radiation for bacterial killing is particularly appealing for sterilization of hospital waste (Pellerin 1994; Tata and Beone 1995; Atwater et al. 1997; Sasaki et al.…”
Section: Introductionmentioning
confidence: 99%
“…To confirm the efficacy of sterilization under these conditions, a variety of microbial challenges was conducted. Prior to integration of the sterilization chamber into the MSAP device a series of tests was performed using PTFE coupons mounted directly inside the chamber (6). The coupons were contaminated with ∼10 6 colony forming units (CFU) of B. stearothermophilus.…”
Section: Resultsmentioning
confidence: 99%
“…ln τ ≈ 33.90 -0.2535T (6) within a microbially vulnerable system, a closed sterile recirculating loop containing 20 mL of SYE broth was attached to the MSAP. The recirculating loop was prepared using a 25 mm × 150 mm glass culture tube connected to MSAP inlet and outlet ports via 0.32 cm i.d.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation