2020
DOI: 10.1016/j.nima.2020.164440
|View full text |Cite
|
Sign up to set email alerts
|

Miniaturized read-out interface “Spectrig MAPD” dedicated for silicon photomultipliers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 7 publications
0
15
0
Order By: Relevance
“…Gamma-ray measurements were carried out in the SPECTRIG MAPD module, where the temperature was . The detailed information about the SPECTRIG MAPD module was presented in 22 . During measurement with SPECTRIG MAPD following parameters were selected: gate width – 227 nsec, variable gain – 1 dB (for M MAPD-3NM-II) and 10 dB (for MAPD-3NM-I), threshold – 6 mV, applied voltage – 54.5 V, 55.8 V (for MAPD-3NM-II) and 76.5 V (for MAPD-3NM-I).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Gamma-ray measurements were carried out in the SPECTRIG MAPD module, where the temperature was . The detailed information about the SPECTRIG MAPD module was presented in 22 . During measurement with SPECTRIG MAPD following parameters were selected: gate width – 227 nsec, variable gain – 1 dB (for M MAPD-3NM-II) and 10 dB (for MAPD-3NM-I), threshold – 6 mV, applied voltage – 54.5 V, 55.8 V (for MAPD-3NM-II) and 76.5 V (for MAPD-3NM-I).…”
Section: Resultsmentioning
confidence: 99%
“…Conventional scintillation detectors based on vacuum photomultiplier tubes (PMT) do not meet these specific operational conditions. Therefore, scintillation detectors based on new photosensors are quite promising candidates that meet the requirements much better, and focusing on their further development is in high demand 9 22 . Many research teams focus on the development of scintillation detectors based on micro pixel avalanche photodiodes (MAPD) or silicon avalanche photomultipliers (SiPM) 15 26 .…”
Section: Introductionmentioning
confidence: 99%
“…Gamma Gamma-ray measurements were carried out in the SPECTRIG MAPD module, where the temperature was 23.5 • C. The detailed information about the SPECTRIG MAPD module was presented in 22 . During measurement with SPECTRIG MAPD following parameters were selected: gate width -227 nsec, variable gain -1 dB (for M MAPD-3NM-II) and 10 dB (for MAPD-3NM-I), threshold -6 mV, applied voltage -54.5 V, 55.8 V (for MAPD-3NM-II) and 76.5 V (for MAPD-3NM-I).…”
Section: Radionuclide Activity [Kbq] X-ray [Kev]mentioning
confidence: 99%
“…Conventional scintillation detectors based on vacuum photomultiplier tubes (PMT) do not meet these specific operational conditions. Therefore, scintillation detectors based on new photosensors are quite promising candidates that meet the requirements much better, and focusing on their further development is in high demand [9][10][11][12][13][14][15][16][17][18][19][20][21][22] . Many research teams focus on the development of scintillation detectors based on micro pixel avalanche photodiodes (MAPD) or silicon avalanche photomultipliers (SiPM) [15][16][17][18][19][20][21][22][23][24][25][26] .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation