2017
DOI: 10.1007/s00064-016-0478-0
|View full text |Cite
|
Sign up to set email alerts
|

Minimal-invasive Versorgung intraartikulärer Fersenbeinfrakturen mit dem 2‑Punkt-Distraktor

Abstract: Of 212 calcaneal fractures, 182 were treated with this technique. Wound healing complication rate was 2.7%; 4.7% of patients required secondary arthrodesis of the subtalar joint.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 7 publications
0
7
0
1
Order By: Relevance
“…While orthoses are in the focus of non-operative therapy in foot-related diseases [15], the use of aids and supporting devices in the treatment of fractures is often totally neglected. Usually, short rehabilitation protocols are provided without too much into detail [16]. Therefore, reliable protocols evaluating the use of the often applied orthotic devices appear to be just as necessary as a standardized procedure for the operation.…”
Section: Discussionmentioning
confidence: 99%
“…While orthoses are in the focus of non-operative therapy in foot-related diseases [15], the use of aids and supporting devices in the treatment of fractures is often totally neglected. Usually, short rehabilitation protocols are provided without too much into detail [16]. Therefore, reliable protocols evaluating the use of the often applied orthotic devices appear to be just as necessary as a standardized procedure for the operation.…”
Section: Discussionmentioning
confidence: 99%
“…The posterior part of ST was the highest among the three, while the all parts exceeded 4 mm (the diameter of ST screw was usually 4 or 3.5 mm). 15,16 Although a 4-mm-diameter screw would be safe and suitable for ST fixation in most cases if under proper usage, the volume of ST in male was greater than in female. Therefore, the diameter of the ST screw should be 4.0 mm in male and 3.5 mm in female.…”
Section: Discussionmentioning
confidence: 99%
“…значительно меньше подобных исследований посвящено сравнению откры- тых способов репозиции с чрескожными. В то же время в целом ряде публикаций серии случаев сообщается о хорошем качестве репозиции при применении чрескожных техник [21,25,26]. Мы предполагаем, что, если соблюдать определенные правила чрескожной репозиции при вдавленных переломах, хорошее и отличное положение отломков достижимо.…”
Section: Discussionunclassified