“…Therefore, for the sensors applied in this condition, the operating temperature should be higher than the environment temperature. Mixed potential type electrochemical sensors using YSZ (Yttria-stabilized Zirconia) solid electrolyte have good hightemperature stability, structure simplicity, and low costs, [21][22][23][24][25] and are widely used to detect different ambient pollution gases including NOx, [26][27][28] CO, 29 NH 3 , 21,22,30 H 2 , 31 H 2 S, 32 and VOCs 33,34 in harsh environment. Thus, it can be one of the most appropriate choices for SO 2 monitor in the exhaust gases from combustion.…”