1999
DOI: 10.1080/00150199908210567
|View full text |Cite
|
Sign up to set email alerts
|

Modeling of multilayer piezoelectric structures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2008
2008
2012
2012

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…For this crystallographic cut, the velocity of the longitudinal plane waves is 6781 m/s and the coupling coefficientK t is equal to 0.564 as it can be seen respectively in Figs. 11a and 7 of [36]. It can be noticed that an error has appeared in [36] since the numerical value ofK t was given to be equal to 0.6 instead of 0.564.…”
Section: Pulse-echo Responsementioning
confidence: 97%
See 2 more Smart Citations
“…For this crystallographic cut, the velocity of the longitudinal plane waves is 6781 m/s and the coupling coefficientK t is equal to 0.564 as it can be seen respectively in Figs. 11a and 7 of [36]. It can be noticed that an error has appeared in [36] since the numerical value ofK t was given to be equal to 0.6 instead of 0.564.…”
Section: Pulse-echo Responsementioning
confidence: 97%
“…11a and 7 of [36]. It can be noticed that an error has appeared in [36] since the numerical value ofK t was given to be equal to 0.6 instead of 0.564. This comes from the fact that the computation was led for a numerical pre-stress of +3 GPa instead of +2 GPa.…”
Section: Pulse-echo Responsementioning
confidence: 97%
See 1 more Smart Citation
“…6. 16 The experimental frequency dependence of real and imaginary parts of the impedance is fitted with ten homogeneous layers (Fig. 7), the parameters to be adjusted are listed in Table 3.…”
Section: Characterisation Of Graded Porosity Piezoceramic Samplementioning
confidence: 99%
“…Usually these multi-layered devices can elaborate original transducers such as Dual-frequency or Barker Code transducers or 2-D array elements with relative low electrical impedance, which lead to a greater sensitivity compared with single-layer element (Desmare, 1999). If they are made of piezoelectric polymeric materials, these devices can also offer some advantages over piezoelectric ceramic transducers, including flexibility, ease of preparing large sheets and the ability to undergo large deflections without damage (Marcus, 1984).…”
Section: Introductionmentioning
confidence: 99%