2019
DOI: 10.11591/ijpeds.v10.i1.pp151-159
|View full text |Cite
|
Sign up to set email alerts
|

Modelling and design of PID controller for voltage control of AC hybrid micro-grid

Abstract: <span>The growing demand for power that needs to be remotely transported creates a fast and effective solution of Distributed Energy Resources (DERs) integration. Distributed Energy Resources (DERs) can lessen the electrical and physical distance between load loss and generator, transmission and distribution, and the level of carbon emissions. Such challenges can be overcome by using microgrids, which combine various types of DERs without interrupting the grid operation, allowing the power system to dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 13 publications
0
14
1
Order By: Relevance
“…Therefore, the THD value after applying shunt HAPF is in parallel with the standard requirement. However, compared to the obtained result of THD value with respect to the previous research done in [10,[18][19][20][21][22][23], the THD value is 2.60% slightly higher than the simulation result obtained in this research.…”
Section: Harmonic Compensation Using Different Type Of Filterscontrasting
confidence: 80%
“…Therefore, the THD value after applying shunt HAPF is in parallel with the standard requirement. However, compared to the obtained result of THD value with respect to the previous research done in [10,[18][19][20][21][22][23], the THD value is 2.60% slightly higher than the simulation result obtained in this research.…”
Section: Harmonic Compensation Using Different Type Of Filterscontrasting
confidence: 80%
“…The programmable load shedding [20][21][22] is carried out using Arduino. The safety of the system is taken into consideration and a system security password is programmed to restrict the accessibility.…”
Section: Programmable Load Sheddingmentioning
confidence: 99%
“…The loads observed required real and reactive powers under various operation conditions to maintain control of frequency and voltage. The following control strategies were introduced: real and reactive control strategy, real and reactive power constraint, real power priority constraint, and PF-QV control strategy [5][6]. A different study of MG design included designing a visualization tool to explain the result of sizing of RES and its effectiveness under various loads and bring attention of operators to where the power is generated and consumed [7].…”
Section: Introductionmentioning
confidence: 99%