2010
DOI: 10.1002/fuce.200900082
|View full text |Cite
|
Sign up to set email alerts
|

Modelling and Performance Evaluation of Solid Oxide Fuel Cell for Building Integrated Co‐ and Polygeneration

Abstract: Models of fuel cell based combined heat and power systems, used in building energy performance simulation codes, are often based on simple black or grey box models. To model a specific device, input data from experiments are often required for calibration. This paper presents an approach for the theoretical derivation of such data. A generic solid oxide fuel cell (SOFC) system model is described that is specifically developed for the evaluation of building integrated co‐ or polygeneration. First, a detailed co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
10
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(10 citation statements)
references
References 38 publications
0
10
0
Order By: Relevance
“…Polygeneration and energy integration are promising tools for achieving better efficiency in the use of natural resources and, in most cases, also reducing the environmental impacts generated [2]. Examples of the application of polygeneration systems include the commercial [7][8][9], domestic [10][11], and industry [12][13] sectors Some consumption units, such as hospitals, exhibit high energy consumption and require continuous and simultaneous electric and thermal energy [14][15][16]. Therefore, hospitals are excellent units with potential for deploying polygeneration systems, as their comfort conditions and electricity, hot water, heating and air conditioning demands must be continuously met.…”
Section: Introductionmentioning
confidence: 99%
“…Polygeneration and energy integration are promising tools for achieving better efficiency in the use of natural resources and, in most cases, also reducing the environmental impacts generated [2]. Examples of the application of polygeneration systems include the commercial [7][8][9], domestic [10][11], and industry [12][13] sectors Some consumption units, such as hospitals, exhibit high energy consumption and require continuous and simultaneous electric and thermal energy [14][15][16]. Therefore, hospitals are excellent units with potential for deploying polygeneration systems, as their comfort conditions and electricity, hot water, heating and air conditioning demands must be continuously met.…”
Section: Introductionmentioning
confidence: 99%
“…They also analyzed the amount of power generation and the increase in temperature of the preheated air through the connected operation using a stack [11]. Kazempoor et al analyzed the modeling of the SOFC stack and system performance through simulation, and numerically assessed the performance of the cogeneration system for buildings connected to the SOFC [12]. Recently, many insightful studies on the design and development of new heat exchangers have been conducted to reduce the flow non-uniformity and heat dissipation effect generated during high-temperature heat transfer [13].…”
Section: Introductionmentioning
confidence: 99%
“…Over the past years there have been numerous modeling efforts of dynamic SOFCs with system-level simulations in mind [4,2,5,12,20,25,39,48,49,50,26], including both lumped and spatially resolved models. Typically, these models include numerous simplifications of the physical processes occurring in the cell such as internal reforming, mass transport, and electrochemical kinetics.…”
Section: Introductionmentioning
confidence: 99%