MELECON 2008 - The 14th IEEE Mediterranean Electrotechnical Conference 2008
DOI: 10.1109/melcon.2008.4618444
|View full text |Cite
|
Sign up to set email alerts
|

Modelling of information system using object-oriented approach

Abstract: The paper discusses an information system for control and supervision of power transmission network in the Republic of Croatia. For upgrading the existing system, various types of information models have been analyzed and compared to find a model that would satisfy the needs of an efficient management and control of an electric power system and electricity market. The models analyzed include a device model, an object-oriented approach model, and the models based on IEC standards. Examples are given for applica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Also suggested are the addresses according to IEC61850 for SIPROTEC 5 generations. For others types of IED it needs to be further defined [4]. 3 Independently another program system "Operating Events Statistics" (OES) monitors the availability of transmission network units over a one-year period.…”
Section: New Process For Advanced Equipment Management Standardizatio...mentioning
confidence: 99%
See 2 more Smart Citations
“…Also suggested are the addresses according to IEC61850 for SIPROTEC 5 generations. For others types of IED it needs to be further defined [4]. 3 Independently another program system "Operating Events Statistics" (OES) monitors the availability of transmission network units over a one-year period.…”
Section: New Process For Advanced Equipment Management Standardizatio...mentioning
confidence: 99%
“…For each type of equipment like relay prot measurement, process information, auxiliary systems th control etc.). This classification and unique information is The catalogue contains information of processing of sign Also suggested are the addresses according to IEC61850 types of IED it needs to be further defined [4].…”
Section: New Process For Advanced Equipment Management Standardizatio...mentioning
confidence: 99%
See 1 more Smart Citation
“…To give the model better results [12], additional efforts have been made to the basic intelligent alarm processing algorithm, with a relay protection model and real time protection data from the SCADA system. In the analysis, it is important to distinguish the relay protection function that isolated the failure on network element where the problem appeared, from the protection function that tripped to isolate the disturbance in other parts of the network due to overload or malfunction in the primary protection.…”
Section: Modelling Of Protection Data From Scada For Iapmentioning