1994
DOI: 10.1016/0022-0728(94)87125-6
|View full text |Cite
|
Sign up to set email alerts
|

Modification of the Pitzer equations for application to electrolyte + polar non-electrolyte mixtures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0

Year Published

1996
1996
2021
2021

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 32 publications
(23 citation statements)
references
References 17 publications
0
23
0
Order By: Relevance
“…In order to make sure of the accuracy of the determined mean activity coefficients values, the Na-ISE was each time calibrated in standard NaCl solutions with concentration range (1 to 10 À4 ) mol Á kg À1 before performing each series of measurements in mixed electrolyte system [27][28][29]. The corresponding slope and the experimental standard potential are presented in table 2.…”
Section: Experimental Mean Activity Coefficient Of Nacl In the Mixturementioning
confidence: 99%
“…In order to make sure of the accuracy of the determined mean activity coefficients values, the Na-ISE was each time calibrated in standard NaCl solutions with concentration range (1 to 10 À4 ) mol Á kg À1 before performing each series of measurements in mixed electrolyte system [27][28][29]. The corresponding slope and the experimental standard potential are presented in table 2.…”
Section: Experimental Mean Activity Coefficient Of Nacl In the Mixturementioning
confidence: 99%
“…In order to make sure of the accuracy of the determined mean activity coefficients values, the electrode pair of Co 2+ -ISE and Ag-AgCl were each time calibrated in standard CoCl 2 solutions with concentration range (1 to 10 À4 ) mol Á kg À1 before performing each series of measurements in mixed electrolyte systems [26][27][28]. The corresponding slope (s) and the experimental standard potential (E 0 ) are presented in table 2.…”
Section: Experimental Mean Activity Coefficient Of Cocl 2 In the Mixturementioning
confidence: 99%
“…In order to make sure of the accuracy of the values of the mean activity coefficients determined, the Ni 2+ -ISE was calibrated in standard NiCl 2 solutions each time in the concentration range (1 to 10 À4 ) mol Á kg À1 before performing each series of measurements in mixed electrolyte systems [28][29][30]. The corresponding slope (s) and the experimental standard potential (E 0 ) are presented in table 3.…”
Section: Tablementioning
confidence: 99%