2021
DOI: 10.1109/tpel.2021.3065028
|View full text |Cite
|
Sign up to set email alerts
|

Modulation for Cascaded Multilevel Converters in PV Applications With High Input Power Imbalance

Abstract: Cascaded multilevel inverters, such as the cascaded H-Bridge (CHB) converter, are an attractive solution for multistring photovoltaic (PV) systems, because they enable direct connection to the medium voltage grid and maximum power point tracking of multiple strings. As a challenge of the topology, the operation with high power imbalance in the strings is constrained by the over-modulation. This limitation is analyzed for sinusoidal modulation and the impact on the maximum power imbalance is demonstrated. For i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(6 citation statements)
references
References 38 publications
0
6
0
Order By: Relevance
“…Extracting the maximum power from a PV system is essential for optimizing its use, so operating it at the maximum power point (MPP) condition is necessary [31][32][33][34][35][36][37]. The MPPT algorithm based on incremental conductance (INC) is employed to utilize the maximum permissible PV power.…”
Section: Maximum Power Point Tracking (Mppt)mentioning
confidence: 99%
“…Extracting the maximum power from a PV system is essential for optimizing its use, so operating it at the maximum power point (MPP) condition is necessary [31][32][33][34][35][36][37]. The MPPT algorithm based on incremental conductance (INC) is employed to utilize the maximum permissible PV power.…”
Section: Maximum Power Point Tracking (Mppt)mentioning
confidence: 99%
“…By substituting ( 6) into (4), the coefficients are obtained, which are used to calculate the fundamental component in (5). Consequently, the fundamental frequency component of the clamped signal F c (ϕ) is derived in (7). On the other hand, the fundamental frequency component of the non-clamped signal F nc (ϕ) can be simply found by subtracting F c (ϕ, α) from the total modulation index 2M .…”
Section: Voltage Balancing Capabilitymentioning
confidence: 99%
“…In some applications, either the unbalanced loading power is unavoidable or the loading power of each cell is controlled to be unbalanced on purpose. The multi-string photovoltaic systems, where each string is connected to the respective DC bus, is one of the representative examples [4]- [7]. In such systems, a mismatch in the operating conditions inherently results in the unbalanced power generation among the strings.…”
Section: Introductionmentioning
confidence: 99%
“…In such a case, the PV power production can no longer be transferred to the storage, thus, to avoid an undesirable complete curtailment of the available PV power, the system should be able to invert its operation with the aim of providing the produced PV power to the grid. It means that the system must now work as a grid-connected double-stage PV CHB inverter [12][13][14].…”
Section: Introductionmentioning
confidence: 99%