Modulation Strategy for Multi-Phase Matrix Converter with Common Mode Voltage Elimination and Adjustment of the Input Displacement Angle

Abstract: In the last several years, thanks to the development and continuous improvement of semiconductor switching elements, and the simultaneous increase in interest in multi-phase drives, the investigation into constructing multi-phase converters has been growing. The matrix converter (MC) is considered to be one of the contenders for use in the multi-phase drive. In the context of using MC in the drive, it is expected to eliminate the common mode voltage (CMV). Another important problem is the ability to correct th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…First, the reference voltage of the inverter is obtained, and the angles θ 1 * and θ 2 * of the reference voltage are obtained by PLL. The duty cycles for the inverter d αInv.1 , d βInv.1 , d αInv.2 , and d βInv.2, and the duty cycles of zero vectors d 0Inv.1 and d 0Inv.2 can be calculated according to the angle of reference voltage and (7). After obtaining the duty cycles, the current harmonic contents under different x and y are compared by use of ( 27) and the optimal pulse is obtained.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…First, the reference voltage of the inverter is obtained, and the angles θ 1 * and θ 2 * of the reference voltage are obtained by PLL. The duty cycles for the inverter d αInv.1 , d βInv.1 , d αInv.2 , and d βInv.2, and the duty cycles of zero vectors d 0Inv.1 and d 0Inv.2 can be calculated according to the angle of reference voltage and (7). After obtaining the duty cycles, the current harmonic contents under different x and y are compared by use of ( 27) and the optimal pulse is obtained.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…The block diagram of the duty-cycle correction strategy is shown in Figure 8 the reference voltage of the inverter is obtained, and the angles θ1* and θ2* of the ref voltage are obtained by PLL. The duty cycles for the inverter dαInv.1, dβInv.1, dαInv.2, and and the duty cycles of zero vectors d0Inv.1 and d0Inv.2 can be calculated according to the of reference voltage and (7). After obtaining the duty cycles, the current harmonic co under different x and y are compared by use of ( 27) and the optimal pulse is ob According to ( 17) and ( 18) and the pulse distribution coefficient, the corrected duty of zero vectors can be obtained.…”
Section: Modulation Strategy For Dual-inverter Tsmcs Based On Duty-cy...mentioning
confidence: 99%
See 1 more Smart Citation
“…This section presents an exposition of the research findings, accompanied by a thorough analysis and exhaustive examination. The findings can be visually represented through figures, graphs, tables, and other visual aids, facilitating the reader's comprehension [14], [15]. The conversation can be divided into multiple sub-sections.…”
Section: Interfacing Power Electronics and Its Modulation Strategymentioning
confidence: 99%
“…Input current can be improved by using the current SVM, and output current can keep reliable track of instruction current by using PI regulation. e method is simple and with commendable robustness [30][31][32].…”
Section: Control Strategy Of Load Side In Accelerator Power Supplymentioning