Moisture condensation on building envelopes in differential ventilated spaces in the tropics: quantitative assessment of influencing factors

Abstract: Abstract. Ventilation systems play a significant role in maintaining the indoor thermal and hygric balance. Nevertheless, the systems had been implicated to result in many problems. In the tropical climate, especially for energy efficiency purposes, building spaces are operated with differential ventilation. Such spaces operate on 24-hrs basis, some on 8-hrs while others are either naturally ventilated or served with mechanical supply-exhaust fan systems with non-conditioned outdoor air. This practice had been… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 27 publications
0
1
0
Order By: Relevance
“…Janssens and Hens [22] investigated air leakage as a significant cause of condensation in lightweight roof systems in cold climates and insisted that it is necessary to improve building codes to achieve an adequate air barrier system; however, controlling air leakage is an uncertain practice in construction, which suggests the addition of insulation panels over the air barrier layer. Ali et al [23] investigated condensation issues in unconditioned spaces adjacent to air-conditioned cooling spaces in tropical climates and researched various types and thicknesses of insulation to increase the thermal resistance of adjacent walls. Moon et al [24] conducted a hygrothermal simulation to analyze the risk of mold growth on the walls of balcony spaces in Korean apartment buildings; accordingly, they suggested appropriate ventilation rates and restricted moisture production activities to minimize the risk of mold growth.…”
Section: Field Measurement Setup For On-site Diagnosismentioning
confidence: 99%
“…Janssens and Hens [22] investigated air leakage as a significant cause of condensation in lightweight roof systems in cold climates and insisted that it is necessary to improve building codes to achieve an adequate air barrier system; however, controlling air leakage is an uncertain practice in construction, which suggests the addition of insulation panels over the air barrier layer. Ali et al [23] investigated condensation issues in unconditioned spaces adjacent to air-conditioned cooling spaces in tropical climates and researched various types and thicknesses of insulation to increase the thermal resistance of adjacent walls. Moon et al [24] conducted a hygrothermal simulation to analyze the risk of mold growth on the walls of balcony spaces in Korean apartment buildings; accordingly, they suggested appropriate ventilation rates and restricted moisture production activities to minimize the risk of mold growth.…”
Section: Field Measurement Setup For On-site Diagnosismentioning
confidence: 99%