2020
DOI: 10.1007/s00216-020-03070-0
|View full text |Cite
|
Sign up to set email alerts
|

Molecular insights into symbiosis—mapping sterols in a marine flatworm-algae-system using high spatial resolution MALDI-2-MS imaging with ion mobility separation

Abstract: Waminoa sp. acoel flatworms hosting Symbiodiniaceae and the related Amphidinium dinoflagellate algae are an interesting model system for symbiosis in marine environments. While the host provides a microhabitat and safety, the algae power the system by photosynthesis and supply the worm with nutrients. Among these nutrients are sterols, including cholesterol and numerous phytosterols. While it is widely accepted that these compounds are produced by the symbiotic dinoflagellates, their transfer to and fate withi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 30 publications
(21 citation statements)
references
References 53 publications
0
20
0
1
Order By: Relevance
“…Matrix application and data acquisition. The matrix 2′,5′-dihydroxyacetophenone (DHAP; Merck) was applied by sublimation and the data were acquired on a modified timsTOF fleX instrument (Bruker Daltonics, Bremen, Germany) (Soltwisch et al, 2020) as described in (Bien et al, 2021). The mass resolving power of this hybrid QTOF-type instrument is about 40,000 (fwhm) in the investigated m/z range of 300-1500.…”
Section: Maldi-2-msimentioning
confidence: 99%
“…Matrix application and data acquisition. The matrix 2′,5′-dihydroxyacetophenone (DHAP; Merck) was applied by sublimation and the data were acquired on a modified timsTOF fleX instrument (Bruker Daltonics, Bremen, Germany) (Soltwisch et al, 2020) as described in (Bien et al, 2021). The mass resolving power of this hybrid QTOF-type instrument is about 40,000 (fwhm) in the investigated m/z range of 300-1500.…”
Section: Maldi-2-msimentioning
confidence: 99%
“…Laser-induced post-ionization was achieved using a diode-pumped, actively Q-switched, frequency-quadrupled Nd:YAG laser operated at 1 kHz (NL 204-1k-FH, EKS-PLA, Vilnius, Lithuania) as described previously. 12 The instrument was operated in positive ion mode, and ions between m / z 300 and 800 were accumulated from 769 laser shots per 50 μm pixel. For TIMS analysis, a ramp time of 769 ms was chosen including a range for 1/ K 0 from 1.1 to 1.75 Vs cm −2 .…”
Section: Methodsmentioning
confidence: 99%
“…10 To overcome these issues, we here assessed, for the rst time, the use of laser-induced post-ionization (MALDI-2), combined with trapped ion mobility separation (TIMS) (MALDI-2-TIMS) in the identication and distribution analysis of isobaric derivatized androgen in a murine tumour xenogra model. MALDI-2 is a recently introduced method for enhanced MSI of numerous classes of biomolecules including sterols, 12 in tissue sections at high lateral resolution. 13 In this proof of concept study, two derivatization reagents, namely Girard-T (GT) and Dansyl Hydrazine (DS) were evaluated using a timsTOF eX MALDI-2 platform from Bruker.…”
Section: Introductionmentioning
confidence: 99%
“…Critical parameters for initiation of the secondary ionization processes are pressure of the cooling gas in the ion source, laser wavelength, pulse energy, and delay between the two laser pulses. The technology could enable sensitive MALDI-MS imaging with a lateral resolution in the low micrometer range (Soltwisch et al, 2015;Soltwisch et al, 2020;Bien et al, 2021b).…”
Section: New Post-ionization Laser-enhanced Ion Sourcesmentioning
confidence: 99%