2015
DOI: 10.1093/rpd/ncv401
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring Dose–length Product in Computed Tomography of the Chest Considering Sex and Body Weight

Abstract: Dose-length product (DLP) is widely used as an indicator of the radiation dose in computed tomography. The aim of this study was to investigate the significance of sex and body weight in DLP-based monitoring of the radiation dose. Eight hundred computed tomographies of the chest performed using four different scanners were analysed. The DLP was compared with body weight by linear regression in men and women separately. The DLP was positively correlated with body weight, and dependence on sex and weight differe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
1

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(14 citation statements)
references
References 19 publications
1
12
1
Order By: Relevance
“…Weight showed an excellent positive correlation with DLP, and was indicated to be more suitable for radiation dose monitoring than height, BMI and BSA. In a previous study on chest CT, the correlation coefficients between DLP and weight ranged from 0.762 to 0.895 for four CT scanners from three vendors (Inoue et al 2016), while the correlation coefficient in this study was much higher (0.985). This difference Values are mean ± standard deviation.…”
Section: Discussioncontrasting
confidence: 72%
See 1 more Smart Citation
“…Weight showed an excellent positive correlation with DLP, and was indicated to be more suitable for radiation dose monitoring than height, BMI and BSA. In a previous study on chest CT, the correlation coefficients between DLP and weight ranged from 0.762 to 0.895 for four CT scanners from three vendors (Inoue et al 2016), while the correlation coefficient in this study was much higher (0.985). This difference Values are mean ± standard deviation.…”
Section: Discussioncontrasting
confidence: 72%
“…When strong attenuation is expected, the AEC increases the tube current and, consequently, radiation exposure, to prevent excessive increase in image noise. As a result, a higher radiation dose is delivered to larger patients than to smaller patients, and positive correlations between patients' weight and CT dose have been reported (Israel et al 2010, Iball and Tout 2014, Inoue et al 2016. The AEC also manipulates radiation exposure along the slice location in an imaging series.…”
Section: Introductionmentioning
confidence: 99%
“…When using AEC, DLP varies with body size and correlates well with body weight [ 20 , 21 , 22 ]. Because a higher DLP in a larger patient does not imply an excessive radiation dose beyond that required, body size should be considered in radiation dose management.…”
Section: Overview Of Ct Radiation Dose Managementmentioning
confidence: 99%
“…We determine median doses for standard-sized patients and compare them to the Japanese DRLs [ 23 ] every year and early after changing parameters. However, the relationship between body size and dose varies with the CT scanner and imaging protocol [ 20 , 21 ], and it is desirable to evaluate doses for various body sizes. DRLs for different body sizes have been reported [ 24 ].…”
Section: Overview Of Ct Radiation Dose Managementmentioning
confidence: 99%
See 1 more Smart Citation