Monitoring of a second‐order reaction by electronic absorption spectroscopy using combined chemometric and kinetic models

Abstract: This paper reports the application of 11 methods for obtaining kinetic constants from a second-order reaction, that between phenylhydrazine and benzophenone. In this type of reaction the number of absorbing species is lower than the number of steps in the reaction minus one, resulting in a rankdeficient response matrix. The methods used include traditional univariate curve fitting, classical least squares using previously recorded pure spectra, alternating least squares methods with both kinetic and non-negati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2004
2004
2018
2018

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 43 publications
(53 reference statements)
0
6
0
Order By: Relevance
“…The pharmaceutical industry, driven by the FDA ' s PAT initiative, can be seen as a forerunner. This is refl ected by the observation that many references in this chapter are (co -) authored by representatives from pharmaceutical companies like Glaxo Wellcome 21,29 and GlaxoSmithKline, 8,10,36,39,40 Astra Zeneca, 19,38 Novartis 28 and Eli Lilly. 18 As with other spectroscopic techniques, UV -vis spectroscopy can readily be used in lab -based R & D. The implementation as process monitors, scanning for deviations from the set state, is certainly an added value and low in maintenance requirements.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The pharmaceutical industry, driven by the FDA ' s PAT initiative, can be seen as a forerunner. This is refl ected by the observation that many references in this chapter are (co -) authored by representatives from pharmaceutical companies like Glaxo Wellcome 21,29 and GlaxoSmithKline, 8,10,36,39,40 Astra Zeneca, 19,38 Novartis 28 and Eli Lilly. 18 As with other spectroscopic techniques, UV -vis spectroscopy can readily be used in lab -based R & D. The implementation as process monitors, scanning for deviations from the set state, is certainly an added value and low in maintenance requirements.…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, the difference beween absorbances becomes dominated by noise close to the isosbestic points, which proved computationally challenging in a study by Thurston et al 10 There, those areas were excluded from the computation.…”
Section: Isosbestic Pointsmentioning
confidence: 99%
“…52 For readers who would like to get more detailed information about chemometrics, a multitude of literature is available. [53][54][55][56][57][58][59][60][61][62][63][64][65][66][67][68][69][70] Near infrared spectroscopy for polymer research A literature search using the SciFinder database of the American Chemical Society (ACS)� shows an increase in the number of publications dealing with NIR spectroscopy and polymers ( Figure 2)�. From 1960-1980 only three papers appeared and from 2000-2006 more than 160 manuscripts were published.…”
Section: Chemometricsmentioning
confidence: 99%
“…[5][6][7][8][9][10][11] Only a limited number of studies include the second order reactions of the form U + V → W, [12][13][14] which are industrially important. Second order consecutive reactions,…”
Section: Introductionmentioning
confidence: 99%