Monitoring of electro-mechanical system "diesel-synchronous generator"

Abstract: A lot of methods exist for the diagnostics of synchronous generators and diesel engine installations. One of these methods is the diagnostics with the help of currents and voltages spectrum analysis. The spectral composition of the output currents and voltages is influenced by technical condition of the synchronous generator -wear of bearing units, shortcircuit of some turns of windings, etc. Such approach to the monitoring of the electro-mechanical "diesel-generator" system gives an opportunity to discover fa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
1
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 9 publications
(8 reference statements)
0
1
0
Order By: Relevance
“…The mathematical model of the electromagnetic transient process of the diesel generator includes the stator voltage balance equation and the rotor winding electromagnetic transient equation of the synchronous generator. As the rotor of the generator is rigidly connected with the diesel crankshaft, then all the processes in the diesel cause the changing distribution of the magnetic flux in the air gap and, therefore, the spectral composition of the output current and voltage of the synchronous generator [28] The generator model is described as follows:…”
Section: Mathematical Model For the Generatormentioning
confidence: 99%
“…The mathematical model of the electromagnetic transient process of the diesel generator includes the stator voltage balance equation and the rotor winding electromagnetic transient equation of the synchronous generator. As the rotor of the generator is rigidly connected with the diesel crankshaft, then all the processes in the diesel cause the changing distribution of the magnetic flux in the air gap and, therefore, the spectral composition of the output current and voltage of the synchronous generator [28] The generator model is described as follows:…”
Section: Mathematical Model For the Generatormentioning
confidence: 99%
“…The basis for the SG mathematical model is the system of equations for voltages in phase coordinates [19]- [21]. The basis for the mathematical model of synchronous generator is the system of Park-Goreva equations.…”
Section: Mathematical Model Of Synchronous Generatormentioning