2010
DOI: 10.3989/ic.09.045
|View full text |Cite
|
Sign up to set email alerts
|

Monitorización de variables medioambientales y energéticas en la construcción de viviendas protegidas: Edificio Cros-Pirotecnia en Sevilla

Abstract: SUMMARY This work is part of the research project known as Efficacia: Reduction of energy consumption and environmental impact of the construction of subsidised housing inPalabras clave: Monitorización, demanda energética, eficiencia energética, ahorro energético, viviendas protegidas.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0
8

Year Published

2013
2013
2017
2017

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 27 publications
(23 citation statements)
references
References 0 publications
1
14
0
8
Order By: Relevance
“…During the summer season, the ambient temperature is higher and the inlet temperature of cold water also increases. Other research [15] verified the results obtained for Seville with inlet temperature of cold water. Another relevant factor is the reference temperature of DHW.…”
Section: Temperature Differencesupporting
confidence: 66%
“…During the summer season, the ambient temperature is higher and the inlet temperature of cold water also increases. Other research [15] verified the results obtained for Seville with inlet temperature of cold water. Another relevant factor is the reference temperature of DHW.…”
Section: Temperature Differencesupporting
confidence: 66%
“…Investigaciones realizadas sobre consumos de energía reales de viviendas sociales localizadas en el área meridional española refl ejan unos valores que están por debajo de los promedios indicados como de referencia para la Califi cación Energética (11). De esta manera, las inversiones de rehabilitación de este tipo de edifi cios mediante la modifi cación de sus envolventes, habitualmente fachadas y huecos, suelen ser muy poco efectivas y no rentables.…”
Section: Introductionunclassified
“…Research carried out on the actual energy consumption of social housing located in the south of Spain shows values below the averages stated as a reference for Energy Qualification (11). As a result, investments in the retrofitting of this type of building by modifying the envelope, usually façades and openings, do not tend to be effective or cost efficient.…”
Section: Introductionmentioning
confidence: 99%
“…Examples of monitored buildings show that real occupation profiles may be quite different from assumptions based on standard profiles (20). This is a typical problem brought about by the lack of connection between design and performance data.…”
Section: Interlinking the Phases Of The Building Life Cyclementioning
confidence: 98%