Monte Carlo calculations of an Elekta Precise SL-25 photon beam model

Abstract: BackgroundMonte Carlo (MC) simulations have been used extensively for benchmarking photon dose calculations in modern radiotherapy using linear accelerators (linacs). Moreover, a major barrier to widespread clinical implementation of MC dose calculation is the difficulty in characterising the radiation source using data reported from manufacturers.PurposeThis work aims to develop a generalised full MC histogram source model of an Elekta Precise SL-25 linac (electron exit window, target, flattening filter, moni… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…The PDD for four high-energy photon energies of 4 MV, 6 MV, 10 MV, 18 MV were modeled in this study. The measurements data were 6 MV, 10 MV (Elekta infinity, Stockholm, Sweden, and Varian trueBeam, Palo Alto, Ca), while 4 MV and 18 MV were published data [ 7 , 8 ].…”
Section: Methodsmentioning
confidence: 99%
“…The PDD for four high-energy photon energies of 4 MV, 6 MV, 10 MV, 18 MV were modeled in this study. The measurements data were 6 MV, 10 MV (Elekta infinity, Stockholm, Sweden, and Varian trueBeam, Palo Alto, Ca), while 4 MV and 18 MV were published data [ 7 , 8 ].…”
Section: Methodsmentioning
confidence: 99%
“…72 The MCNP code is available to the worldwide user community, subject to USA national security restrictions and distributed through the Radiation Safety Information Computational Center, part of Oak Ridge National Laboratory. MCNP has been applied to a wide range of medical physics problems 73 including the modelling of medical linear accelerators, [74][75][76][77][78] and imaging systems such as radiotherapy electronic portal imaging devices (EPIDs), [79][80][81] CT 82 and PET/CT. 83 MCNP has also been used to develop models for kV intraoperative radiotherapy, 84,85 Brachytherapy, [86][87][88] proton therapy 89,90 and gamma irradiator devices 91,92 including the Leksell Gamma Knife 93,94…”
Section: Mcnpmentioning
confidence: 99%
“…The MC models were compared to measure dosimetry profile data in homogeneous water and homogeneous phantoms containing air, bone and lung equivalent materials. 18 Toossi et al used the MCNPX code to simulate the 8, 12 and 14 MeV electron beams generated by a Siemens Primus linear accelerator. Simulated dosimetry profile data were compared to measured data for different field sizes including applicators as part of a commissioning process.…”
Section: X-ray Tube Modellingmentioning