Monte Carlo simulation of the Leksell Gamma Knife$reg$: I. Source modelling and calculations in homogeneous media

Abstract: The Monte Carlo code PENELOPE has been used to simulate photon flux from the Leksell Gamma Knife, a precision method for treating intracranial lesions. Radiation from a single 6OCo assembly traversing the collimator system was simulated, and phase space distributions at the output surface of the helmet for photons and electrons were calculated. The characteristics describing the emitted final beam were used to build a two-stage Monte Carlo simulation of irradiation of a target. A dose field inside a standard s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

8
69
1
2

Year Published

2004
2004
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(80 citation statements)
references
References 23 publications
8
69
1
2
Order By: Relevance
“…Previously, numerous studies were done to analyze the accuracy of plugging in Gamma Knife 7 , 8 , 9 , 10 . There are a set of Monte Carlo (MC) studies which were successfully used for simulating Gamma Knife sources and units itself, including plugging patterns 2 , 7 , 10 , 11 , 12 , 13 , 14 , 15 . Cheung et al (7) employed Monte Carlo general‐purpose code EGS4 implementing PRESTA (parameter reduced electron‐step transport algorithm) algorithm and GAFCHROMIC films (Type MD 55) 16 , 17 to verify the accuracy of LGP TPS when plugged collimators were used.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Previously, numerous studies were done to analyze the accuracy of plugging in Gamma Knife 7 , 8 , 9 , 10 . There are a set of Monte Carlo (MC) studies which were successfully used for simulating Gamma Knife sources and units itself, including plugging patterns 2 , 7 , 10 , 11 , 12 , 13 , 14 , 15 . Cheung et al (7) employed Monte Carlo general‐purpose code EGS4 implementing PRESTA (parameter reduced electron‐step transport algorithm) algorithm and GAFCHROMIC films (Type MD 55) 16 , 17 to verify the accuracy of LGP TPS when plugged collimators were used.…”
Section: Introductionmentioning
confidence: 99%
“…A 9% methacrylic‐based gel was found to give linear doses response up to 40 Gy and is ideal for performing radiosurgery verification (31) . Several studies exist for Gamma Knife verification with polymer gel dosimetry 3 , 13 , 31 , 32 , 33 , 34 , 35 , 36 . Interestingly, 3D measurement based on gel dosimetry has not been used so far for plug planning verification which is the goal of this study.…”
Section: Introductionmentioning
confidence: 99%
“…Most of the simulations performed (Cheung et al 1998, 1999a, 1999b, Xiaowei and Chunxiang 1999, Moskvin et al 2002 have pointed out a good agreement with the GP predictions in the case of a homogeneous phantom. However, differences reaching 25% are found for phantoms with inhomogeneities, near tissue interfaces and dose edges (Cheung et al 2001).…”
Section: Introductionmentioning
confidence: 68%
“…In addition to the dose profiles around the isocenter of the GK, the output factors for the 4, 8 and 14 mm helmets have been obtained. Our findings have been compared with various results obtained with other MC codes, such as EGS4 (Cheung et al 1999a, 1999b, Xiaowei and Chunxiang 1999 or PENELOPE (Moskvin et al 2002), predicted with GP (Elekta 1992, 1998 or measured with different techniques (Ma et al 2000, Tsai et al 2003. Figure 1 shows a scheme of the simplified model of the source channel of the GK.…”
Section: Introductionmentioning
confidence: 86%
“…It is important that the electronic inequilibrium and secondary scattering are taken into account properly. Studies on MC simulations are mainly for the prior LGK systems because the collimator system for prior LGK models is relatively simpler to implement 5 , 6 , 7 , 8 , 9 . To simulate prior LGK, only one dataset of the phase space of photon beams at the distal source channel is needed since this phase space is identical for all 201 sources.…”
Section: Introductionmentioning