Motion-Induced Phase Error Estimation and Correction in 3D Diffusion Tensor Imaging

Abstract: A multishot data acquisition strategy is one way to mitigate B0 distortion and T2∗ blurring for high-resolution diffusion-weighted magnetic resonance imaging experiments. However, different object motions that take place during different shots cause phase inconsistencies in the data, leading to significant image artifacts. This work proposes a maximum likelihood estimation and k-space correction of motion-induced phase errors in 3D multishot diffusion tensor imaging. The proposed error estimation is robust,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
51
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(51 citation statements)
references
References 29 publications
0
51
0
Order By: Relevance
“…The resulting images had 1.6 × 1.6 × 1.6 mm 3 spatial resolution. Iterative image reconstruction included parallel imaging with SENSE [Pruessmann et al, 2001] and correction for field inhomogeneity [Sutton et al, 2003] and motion-induced phase errors [Van et al, 2011], as described previously [Johnson et al, 2014]. …”
Section: Methodsmentioning
confidence: 99%
“…The resulting images had 1.6 × 1.6 × 1.6 mm 3 spatial resolution. Iterative image reconstruction included parallel imaging with SENSE [Pruessmann et al, 2001] and correction for field inhomogeneity [Sutton et al, 2003] and motion-induced phase errors [Van et al, 2011], as described previously [Johnson et al, 2014]. …”
Section: Methodsmentioning
confidence: 99%
“…A wide variety of techniques have been developed to handle these errors. [16][17][18][19][20][21][22][23][24] In addition to subject motion during DWI, these phase errors can be caused by cardiac pulsation or other physiological motions, which may result in nonlinear MPE. The sequence in this work uses a spiral-in readout to acquire a low resolution 2-D navigator image which allows it to be used with most navigator-based motion-correction methods.…”
Section: Navigation For Multishot Diffusionmentioning
confidence: 99%
“…Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging during the diffusion encoding, multi-shot DW techniques require an accompanied phase correction method (7)(8)(9)(10)(11)(12).…”
Section: Original Articlementioning
confidence: 99%
“…When a multi-shot acquisition is needed, such as in the case of high-resolution three-dimensional (3D) diffusion imaging, if the phase error is constant across shots (e.g., eddy-current-induced phase errors) the phase-error dependence can also be ignored. However, with multi-shot imaging in the presence of a time-varying phase error (e.g., MiPe) the signal phase modulation has to be accounted for before the shots are combined (8,9,11,12).…”
Section: Magnitude Stabilizersmentioning
confidence: 99%